Related Experiment Video
Updated: Feb 11, 2026

Procedures of Laboratory Fumigation for Pest Control with Nitric Oxide Gas
Published on: November 24, 2017
Experimental investigation of nitric oxide removal from flue gas using hexamminecobalt(II) solution scrubbing in a
Bing Han1,2, Qinghai Li1,2, Zhen Liu1,2
11 Key Laboratory of Thermal Science and Power Engineering of Ministry of Education, Department of Energy and Power Engineering, Tsinghua University, Beijing, People's Republic of China.
Abstract:
An experimental investigation of operational parameters, including liquid/gas ratio (L/G), inlet nitric oxide (NO) concentration, reaction temperature, and pH value of absorbing agent, on NO removal efficiency with hexamminecobalt(II) solution scrubbing was conducted on a pilot-scale facility to search optimal operation conditions. The experimental results show that NO removal efficiency increased with the pH value of hexamminecobalt solution, while the improving rate dropped gradually. When the reaction temperature increased, the NO removal efficiency increased first and then decreased. At the same time, NO removal efficiency increased with the increasing of L/G and hexamminecobalt concentration, while the removal efficiency did not change much at low NO concentration. The pH of 10.4 and L/G of 16 L/m3 were close to the optimal operation conditions, and the scrubbing temperature fell within a reasonable operation temperature. The experimental results can be used as a reference for the design and operation of scaled-up industrial devices.
More Related Videos
Related Concept Videos
Nitric Oxide Signaling Pathway
Gas Thermometers and the Kelvin Scale
Strong Acid and Base Solutions
Pilot and Numeric Relaying
pH Scale
Oxidation Numbers