Background And Purpose:
A valid and reliable assessment tool is fundamental for evaluating the knowledge of individuals about using oral anticoagulant therapy (OAT). The purpose of this study was to develop a tool to assess knowledge about OAT and provide evidence to support its use in people living in developing countries.
Methods:
Construction and validation: development of items; assessment of face and content validity; pilot study; application of the instrument to a sample of 500 users of OAT to analyze dimensionality, convergent validation, and reliability.
Results:
Analysis of dimensionality suggested a unidimensional instrument. Direct correlation between knowledge of OAT and educational level was confirmed (r = .61, p < .001) (validity of construct). Reliability measured by KR-20 was 0.86.
Conclusions:
The new instrument was shown to be valid and reliable for assessing knowledge of OAT in the population studied.
More Related Videos
07:08Assessment of the Anticoagulant and Anti-inflammatory Properties of Endothelial Cells Using 3D Cell Culture and Non-anticoagulated Whole Blood
Published on: September 5, 2017
04:45Intraoperative Assessment of Resection Margins in Oral Cavity Cancer: This is the Way
Published on: May 10, 2021
Related Concept Videos
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Reliability and Validity
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers