A sensitivity analysis to determine the robustness of STRmix with respect to laboratory calibration

Hannah Kelly1, Jo-Anne Bright1, Maarten Kruijver2

  • 1Institute of Environmental Science and Research Limited, Private Bag 92021, Auckland, 1142, New Zealand.

Related Concept Videos

Area Between Curves: Integrating With Respect to y01:29

Area Between Curves: Integrating With Respect to y

Consider a planar region bounded by two curves that are both written as functions of the vertical variable, y. The left and right boundary curves are continuous between y = c and y = d, and these two horizontal lines define the vertical limits of the region. Because the boundaries depend on y rather than x, the area is most appropriately evaluated using horizontal slices.The area is obtained using the Riemann sum method. The region is divided into many thin horizontal strips, each having an...
68
Area Between Curves: Integrating With Respect to x01:25

Area Between Curves: Integrating With Respect to x

Consider two continuous functions defined on a closed interval from a to b. The region between these curves is bounded vertically by their graphs and horizontally by the endpoints of the interval. The objective is to measure the area of this region.An initial estimate of the area can be obtained by dividing the interval into a large number of narrow vertical strips of equal width. Each strip is approximated by a rectangle whose height is given by the vertical difference between the two...
136
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.5K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
782
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the...
5.0K
Plotting and Calibrating the Root Locus01:19

Plotting and Calibrating the Root Locus

Root loci often diverge as system poles shift from the real axis to the complex plane. Key points in this transition are the breakaway and break-in points, indicating where the root locus leaves and reenters the real axis. The branches of the root locus form an angle of 180/n degrees with the real axis, where n is the number of branches at a breakaway or break-in point.
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
482