Abstract:
The most efficient optimization methodologies in liquid chromatography are based on the modeling and prediction of the chromatographic behavior for each compound in the sample. However, when the column suffers some ageing after the modeling process, predictions may differ significantly from the actual separation. Repeating the modeling is especially troublesome when several columns are involved, as is the case of coupled columns. We propose a shortcut to correct the time and peak profiles in these situations, after evaluating the effects of ageing. The original models are corrected by introducing parameters accounting for column ageing, obtained using the data of a small subset of compounds from those used to model the brand-new column. The ageing parameters are fitted from the discrepancies between the data predicted with the original retention models for the brand-new column and the experimental data measured for the aged column. The approach was developed and tested to predict the chromatographic behavior of 15 sulfonamides, analyzed with individual and tandem columns, using isocratic and gradient elution. Chromatograms more in line with the aged column performance were predicted. The agreement between predictions and experimental data in the aged columns was excellent.
More Related Videos
06:05The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time
Published on: February 19, 2021
07:04Optimization of In vitro Transcription Reaction for mRNA Production Using Chromatographic At-Line Monitoring
Published on: April 4, 2025
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...