Related Experiment Video
Updated: Feb 10, 2026

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Can point shear wave elastography differentiate focal nodular hyperplasia from hepatocellular adenoma
Pavel Taimr1,2, Anne Julia Klompenhouwer3, Maarten G J Thomeer4
1Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
Purpose:
Focal nodular hyperplasia (FNH) and hepatocellular adenoma (HCA) are liver tumors that require different management. We assessed the potential of point shear wave elastography (pSWE) to differentiate FNH from HCA and the interobserver and intraobserver reliability of pSWE in the examination of these lesions and of native liver tissue (NLT).
Methods:
The study included 88 patients (65 FNH, 23 HCA). pSWE was performed by two experienced liver sonographers (observers 1 [O1] and 2 [O2]) and acquired within the lesion of interest and NLT. Group differences, optimal cutoff for characterization and interobserver reliability was assessed with Mann-Whitney-U, area under the ROC curce (AUROC) and intraclass correlation coefficient (ICC). Intraobserver reliability in NLT was assessed in 20 healthy subjects using ICC.
Results:
Median stiffness was significantly higher in FNH than in HCA (7.01 kPa vs 4.98 kPa for O1 (P = 0.017) and 7.68 kPa vs 6.00 kPa for O2 (P = 0.031)). A cutoff point for differentiation between the two entities could not be determined with an AUROC of 0.67 (O1) and 0.69 (O2). Interobserver reliability was good for lesion- stiffness (ICC = 0.86) and poor for NLT stiffness (ICC = 0.09). In healthy subjects, intraobserver reliability for NLT-stiffness was poor for O1 (ICC = 0.23) and moderate for O2 (ICC = 0.62).
Conclusion:
This study shows that pSWE cannot reliably differentiate FNH from HCA. Interobserver and intraobserver reliability for pSWE in NLT were insufficient. Interpretation of results gained with this method should be done with great caution.
More Related Videos
12:18Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
Published on: August 29, 2025
Related Concept Videos
The Wave Nature of Light
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain
Intracellular Signaling Affects Focal Adhesions
Some...
Normal and Shear Force