Related Experiment Video
Updated: Feb 10, 2026

A High Performance Impedance-based Platform for Evaporation Rate Detection
Published on: October 17, 2016
Adaptive nocturnal seizure detection using heart rate and low-complexity novelty detection
Thomas De Cooman1, Carolina Varon1, Anouk Van de Vel2
1Department of Electrical Engineering (ESAT), STADIUS, KU Leuven, Leuven, Belgium; imec, Leuven, Belgium.
Purpose:
Automated seizure detection at home is mostly done using either patient-independent algorithms or manually personalized algorithms. Patient-independent algorithms, however, lead to too many false alarms, whereas the manually personalized algorithms typically require manual input from an experienced clinician for each patient, which is a costly and unscalable procedure and it can only be applied when the patient had a sufficient amount of seizures. We therefore propose a nocturnal heart rate based seizure detection algorithm that automatically adapts to the patient without requiring seizure labels.
Methods:
The proposed method initially starts with a patient-independent algorithm. After a very short initialization period, the algorithm already adapts to the patients' characteristics by using a low-complex novelty detection classifier. The algorithm is evaluated on 28 pediatric patients with 107 convulsive and clinical subtle seizures during 695 h of nocturnal multicenter data in a retrospective study that mimics a real-time analysis.
Results:
By using the adaptive seizure detection algorithm, the overall performance was 77.6% sensitivity with on average 2.56 false alarms per night. This is 57% less false alarms than a patient-independent algorithm with a similar sensitivity. Patients with tonic-clonic seizures showed a 96% sensitivity with on average 1.84 false alarms per night.
Conclusion:
The proposed method shows a strongly improved detection performance over patient-independent performance, without requiring manual adaptation by a clinician. Due to the low-complexity of the algorithm, it can be easily implemented on wearables as part of a (multimodal) seizure alarm system.
More Related Videos
Related Concept Videos
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...

