Related Experiment Video
Updated: Feb 10, 2026

Functionalization and Dispersion of Carbon Nanomaterials Using an Environmentally Friendly Ultrasonicated Ozonolysis Process
Published on: May 30, 2017
Ultrasonic assisted magnetic dispersive solid phase microextraction for pre concentration of serotonin-norepinephrine
Mahdi Ghorbani1, Mahmoud Chamsaz1, Mohsen Aghamohammadhasan2
1Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran.
Abstract:
A simple and sensitive ultrasonic assisted magnetic dispersive solid phase microextraction method (UAMDSPME) coupled with high performance liquid chromatography was developed to determine serotonin-norepinephrine reuptake inhibitor drugs including duloxetine (DUL), venlafaxine (VEN) and atomoxetine (ATO) in human urine, river water and well water samples. A novel and efficient SPME sorbent, magnetic p-Phenylenediamine functionalized reduced graphene oxide Quantum Dots@ Ni nanocomposites (MrGOQDs-PD@ Ni), was prepared and applied for extraction of the analytes. Several effective parameters on the extraction efficiency of the analytes were investigated and optimized with experimental design approach. The performance of MrGOQDs-PD@ Ni as the SPME sorbent for the extraction of DUL, VEN and ATO was then compared with magnetic graphene oxide (MGO@Fe3O4) and magnetic reduced graphene oxide (MrGO@ Ni). Under the optimized conditions for the MrGOQDs-PD@ Ni sorbent, the intra-day relative standard deviations (RSDs, n = 5) and the limits of detections (LODs) were lower than 4.6% and 1.1 ngmL-1, respectively. Moreover, the good linear ranges were observed in wide concentration ranges with R-squared larger than 0.9878. Finally, the enrichment factors in the range of 137-183 and the recovery percentage in the range of 89.2-94.8% were obtained to determine the analytes in the real samples.
More Related Videos
Related Concept Videos
Drugs Affecting GI Tract Motility: Serotonin Receptor Agonists
Drug Concentrations: Measurements
Plasma...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Phase Transitions: Sublimation and Deposition
Molecular and Ionic Solids
Molecular Solids
Molecular crystalline solids, such as ice, sucrose (table sugar), and iodine, are solids that are composed of neutral molecules as their constituent units. These molecules are held together by weak intermolecular forces such as London dispersion forces, dipole-dipole interactions, or hydrogen bonds, which...
Antihypertensive Drugs: Direct Renin Inhibitors