Cementless versus cemented glenoid components in conventional total shoulder joint arthroplasty: analysis from the Australian Orthopaedic Association National Joint Replacement Registry
Related Experiment Video
Updated: Feb 10, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Richard S Page1, Vishal Pai2, Kevin Eng2
1School of Medicine, Deakin University, Geelong, VIC, Australia; Barwon Centre for Orthopaedic Research and Education, Education and Research Centre, St John of God Hospital, Geelong, VIC, Australia; Department of Orthopaedic Surgery, University Hospital Geelong-Barwon Health, Geelong, VIC, Australia.
Background:
Glenoid loosening is a common mode of failure after total shoulder arthroplasty (TSA). Newer cementless glenoid components have been introduced to promote biological fixation with the aim to decrease glenoid loosening. Limited data are available comparing revision rates between cemented and cementless glenoid fixation in TSA. The study aim was to compare the revision rates of cemented and cementless design glenoid components used in conventional TSA performed for the diagnosis of osteoarthritis. The secondary aim was to compare various subclasses of glenoid components.
Methods:
Data were obtained between April 16, 2004, and December 31, 2016, from the Australian Orthopaedic Association National Joint Replacement Registry. Within the study period, 10,805 primary conventional TSAs were identified. The analysis was undertaken for the diagnosis of osteoarthritis, which represented 95.8% of all conventional TSA procedures.
Results:
At 5 years, in patients with primary TSA procedures, those with cemented glenoids had a lower revision rate than those with cementless glenoids: 3.7% versus 17.9% (hazard ratio for entire period, 4.77). The most common revision diagnosis for primary conventional TSA with cementless glenoid fixation was rotator cuff insufficiency (4.4% for cementless vs 0.4% for cemented), instability and/or dislocation (3.8% for cementless vs 0.8% for cemented), and loosening and/or lysis (1.1% for cementless vs 1.1% for cemented).
Conclusions:
Cementless glenoid components in conventional TSA had a significantly higher revision rate than cemented glenoid components. The loosening rates between cemented and cementless glenoid components were similar. Glenoid design and fixation are important considerations when selecting a prosthesis for TSA.
Related Concept Videos
Structural Joints: Synovial Joints
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Structural Joints: Cartilaginous Joints
There are two types of cartilaginous joints:
Synchondrosis
A synchondrosis ("joined by cartilage") is a cartilaginous joint where bones are connected by hyaline cartilage. Synchondrosis may be temporary...
Joints
Structural joint classifications are based on the material that makes up the joint as well as whether or not the joint contains a space between the bones. Joints are structurally classified as fibrous, cartilaginous, or synovial.
Fibrous Joints Are Immovable
The bones of a...
Method of Joints
Since plane truss members are in the same plane, each joint is subjected to a coplanar and concurrent force system. To apply the method of joints, the first step is to...
Introduction to Joints

