Pathological mechanisms of left main stent failure
Hiroyoshi Mori1, Sho Torii1, Emanuel Harari1
1CVPath institute, Gaithersburg, MD, United States.
Background:
Despite the increasing use of left main (LM) percutaneous coronary intervention (LM-PCI), there have been no pathological studies devoted to understanding the causes of LM stent failure. We aimed to systematically determine the pathological mechanisms of LM stent failure.
Methods And Results:
From the CVPath Stent registry, a total of 46 lesions were identified to have LM-PCI. Pathologic stent failure (PSF) was defined as stent thrombosis, restenosis and in-stent chronic total occlusion (CTO). Failed and patent LM stented lesions were pathologically assessed to determine predictors of PSF. Malapposition and uncovered struts were numerically greater in the LM ostium, body, and bifurcation while neointimal thickness was relatively greater in bifurcation and proximal circumflex. In this study cohort, half of the lesions (n = 23) showed PSF. Stent thrombosis (ST, n = 18) was the major mode of PSF followed by in-stent CTO (n = 4) and restenosis (n = 1). Failed lesions showed significantly greater prevalence of malapposition >20% of struts/section (65% vs. 13%, P < 0.01), stent struts crossing an ostial side branch >30% of the circumference (48% vs. 13%, P < 0.01) and uncovered struts >30% (57% vs. 18%, P = 0.03). In multivariate analysis, the prevalence of malapposition >20% was the strongest risk factor for PSF (Odds ratio 8.0, 95% confidence interval 1.8-45.4, P < 0.01) followed by struts crossing an ostial side branch >30% (Odds ratio 4.2, 95% confidence interval 0.8-24.7, P = 0.09).
Conclusion:
Our data demonstrate the main pathological predictors for LM stent failure are malapposition and struts crossing an ostial side branch and suggest that imaging-guided PCI may be important.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Related Concept Videos
Pathophysiology of Heart Failure
Heart Failure I: Introduction
Heart Failure II: Pathophysiology
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...