Objectives:
The purpose of this study was to assess the feasibility of pulmonary vein (PV) isolation using low-intensity collimated ultrasound.
Background:
Contemporary approaches to PV isolation are limited by the technical complexity of mapping and ablation. We describe a novel approach to left atrial anatomic rendering and PV isolation that aims to overcome some of these limitations by using low-intensity collimated ultrasound (LICU) system, which allows for near real-time geometry creation and automated ablation in a porcine model.
Methods:
Twenty swine were anesthetized, and the LICU ablation catheter was placed in the left atrium via percutaneous transseptal access. Ultrasound M-mode-based anatomies of the inferior PVs were successfully created, and ablation was performed under automatic robotic control along a user-defined lesion path. One animal was excluded because of device failure.
Results:
All target PVs in the 19 remaining animals were isolated acutely, requiring a mean of 1.6 applications. Ten animals were sacrificed acutely, and the remaining 9 survived for 35 ± 11 days. Of these 9, 1 animal was excluded from analysis because the index lasso position could not be reliably recreated. PVs in 5 of 8 animals remained isolated at sacrifice. Of the 77 total histological sections, 62 lesions (80.5%) were noted to be transmural. Lesions were homogeneous and characterized by coagulative necrosis and fibrous tissue. The mean myocardial thickness was 2.66 ± 1.80 mm, and the mean lesion depth was 4.28 ± 1.97 mm. No extra cardiac or collateral lesions were noted.
Conclusions:
This study demonstrates the safety and efficacy of a novel noncontact ultrasound mapping and ablation system to produce continuous transmural lesions that can isolate PVs in a porcine model.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
pre-mRNA Processing
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a “cap” to the 5’ end of the growing transcript. In this process, a 5’ phosphate is replaced by modified guanosine that has a methyl group attached to it (7-Methyl...
Sound Intensity
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Pre-mRNA Processing: Modification of pre-mRNA Ends
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a cap to the 5' end of the growing transcript. In this process, a 5' phosphate is replaced by modified guanosine that has a methyl group attached (7-methyl guanosine). This 5' cap helps...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...