Development, Preclinical Validation, and Clinical Translation of a Cardiac Magnetic Resonance - Electrophysiology
Henry Chubb1, James L Harrison2, Steffen Weiss2
1Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.
Objectives:
This study sought to develop an actively tracked cardiac magnetic resonance-guided electrophysiology (CMR-EP) system and perform first-in-human clinical ablation procedures.
Background:
CMR-EP offers high-resolution anatomy, arrhythmia substrate, and ablation lesion visualization in the absence of ionizing radiation. Implementation of active tracking, where catheter position is continuously transmitted in a manner analogous to electroanatomic mapping (EAM), is crucial for CMR-EP to take the step from theoretical technology to practical clinical tool.
Methods:
The setup integrated a clinical 1.5-T scanner, an EP recording and ablation system, and a real-time image guidance platform with components undergoing ex vivo validation. The full system was assessed using a preclinical study (5 pigs), including mapping and ablation with histological validation. For the clinical study, 10 human subjects with typical atrial flutter (age 62 ± 15 years) underwent MR-guided cavotricuspid isthmus (CTI) ablation.
Results:
The components of the CMR-EP system were safe (magnetically induced torque, radiofrequency heating) and effective in the CMR environment (location precision). Targeted radiofrequency ablation was performed in all animals and 9 (90%) humans. Seven patients had CTI ablation completed using CMR guidance alone; 2 patients required completion under fluoroscopy, with 2 late flutter recurrences. Acute and chronic CMR imaging demonstrated efficacious lesion formation, verified with histology in animals. Anatomic shape of the CTI was an independent predictor of procedural success.
Conclusions:
CMR-EP using active catheter tracking is safe and feasible. The CMR-EP setup provides an effective workflow and has the potential to change the way in which ablation procedures may be performed.
More Related Videos
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Preclinical Development: Overview
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...