Related Experiment Video
Updated: Feb 10, 2026

Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice
Published on: May 5, 2022
Real-Time Localization of Ventricular Tachycardia Origin From the 12-Lead Electrocardiogram
John L Sapp1, Meir Bar-Tal2, Adam J Howes1
1The QEII Health Sciences Centre, Halifax, Nova Scotia, Canada.
Objectives:
The aim of this study was to develop rapid computational methods for identifying the site of origin of ventricular activation from the 12-lead electrocardiogram.
Background:
Catheter ablation of ventricular tachycardia in patients with structural heart disease frequently relies on a substrate-based approach, which may use pace mapping guided by body-surface electrocardiography to identify culprit exit sites.
Methods:
Patients undergoing ablation of scar-related VT (n = 38) had 12-lead electrocardiograms recorded during pacing at left ventricular endocardial sites (n = 1,012) identified on 3-dimensional electroanatomic maps and registered to a generic left ventricular endocardial surface divided into 16 segments and tessellated into 238 triangles; electrocardiographic data were reduced for each lead to 1 variable, consisting of QRS time integral. Two methods for estimating the origin of activation were developed: 1) a discrete method, estimating segment of activation origin using template matching; and 2) a continuous method, using population-based multiple linear regression to estimate triangle of activation origin. A variant of the latter method was derived, using patient-specific multiple linear regression.
Results:
The optimal QRS time integral included the first 120 ms of the QRS interval. The mean localization error of population-based regressions was 12 ± 8 mm. Patient-specific regressions can achieve localization accuracy better than 5 mm when at least 10 training-set pacing sites are used; this accuracy further increases with each added pacing site.
Conclusions:
Computational intraprocedure methods can automatically identify the segment and site of left ventricular activation using novel algorithms, with accuracy within <10 mm.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Phase-lead and Phase-lag Controllers
Cancers Originate from Somatic Mutations in a Single Cell