Related Experiment Video
Updated: Feb 10, 2026

Animal Model of Implant-Associated Infections in Mice
Published on: June 27, 2025
Cardiac Implantable Electronic Device Infections: Added Complexity and Suboptimal Outcomes With Previously Abandoned
Ayman A Hussein1, Khaldoun G Tarakji1, David O Martin1
1Sections of Cardiac Electrophysiology and Infectious Disease, Cleveland Clinic, Cleveland, Ohio.
Objectives:
This study sought to assess the impact of previously abandoned leads on the clinical management of cardiac device infections, notably transvenous lead extraction and subsequent clinical course.
Background:
The population of patients with cardiac implantable electronic devices continues to grow with a disproportionate increase in device infections, which are invariably life threatening. A potentially complicating issue is the widely practiced strategy of device lead abandonment at the time of system revision, change, or upgrade, which is affecting an increasing number of patients.
Methods:
The study assessed the impact of previously abandoned leads in a prospectively maintained registry of consecutive patients undergoing percutaneous extraction of infected cardiac devices at the Cleveland Clinic between August 1996 and September 2012. The primary clinical endpoint was complete procedural and clinical success defined as the successful removal of the device and all lead material from the vascular space, in the absence of a major complication.
Results:
Of 1,386 patients with infected cardiac devices, 323 (23.3%) had previously abandoned leads. Failure to achieve the primary endpoint occurred more frequently in patients with abandoned leads (13.0% vs. 3.7%; p < 0.0001). This was primarily due to retention of lead material (11.5% vs. 2.9%; p < 0.0001), which was associated with poor clinical outcomes including higher rates of 1-month mortality (7.4% vs. 3.5% in those without lead remnants). Lead extraction procedures in patients with previously abandoned leads were longer (p < 0.0001), with longer fluoroscopy times (p < 0.0001), and more likely to require specialized extraction tools (94.4% vs. 81.8%; p < 0.0001) or adjunctive rescue femoral workstations (14.9% vs. 2.9%; p < 0.0001). Procedural complications occurred more frequently in patients with previously abandoned leads (11.5% vs. 5.6%; p = 0.0003), which was true for both major (3.7% vs. 1.4%; p = 0.009) and minor complications (7.7% vs. 4.4%; p = 0.02).
Conclusions:
Previously abandoned leads complicate the management of cardiac device infections, leading to worse clinical outcomes.
Related Concept Videos
Electron Transport Chain: Complex I and II
ROS generation is regulated and maintained at moderate levels necessary...
Electron Transport Chain: Complex III and IV
Electron Transport Chains
The ETC is comprised of...
Electron Affinity
Predicting Reaction Outcomes
Electron Behavior
Electrons are negatively charged subatomic particles that are attracted to an orbit around the positively-charged nucleus of an atom. They reside in locations that are associated with energy levels called shells and are further organized into sub-shells and orbitals within each shell.
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the...

