Related Experiment Video
Updated: Feb 10, 2026

Purification and Visualization of Lipopolysaccharide from Gram-negative Bacteria by Hot Aqueous-phenol Extraction
Published on: May 28, 2012
Photochemical device for selective detection of phenol in aqueous solutions
Nianbing Zhong1, Ming Chen, Zhengkun Wang
1Chongqing Key Laboratory of Modern Photoelectric Detection Technology and Instrument, Chongqing Key Laboratory of Fiber Optic Sensor and Photodetector, Chongqing Energy Internet Engineering Center, Chongqing University of Technology, Chongqing 400054, China. nzhong_08@163.com.
Abstract:
We demonstrate that a lab-on-a-chip device (hereafter termed a photochemical phenol sensor) that integrates a photocatalytic long-period fiber grating (PLPFG), fiber Bragg grating (FBG), polymer membrane, ultraviolet (UV) visible light, and microchannels can be exploited to selectively detect phenol in aqueous solutions. The novel PLPFG consisted of a thinned long-period fiber grating (LPFG) and a UV-visible-light-driven Er3+:YAlO3/SiO2/TiO2 (EYST) coating. The polymer membrane with high phenol permselectivity was synthesized using PEBA2533 doped with β-cyclodextrin and was wrapped around the EYST surface, thus forming a microchannel between the membrane and PLPFG to enable the injection and outflow of standard analytes. Subsequently, a Z-shaped microchannel in a PMMA plate was fabricated and employed as a storage chamber for phenol analytes. To realize the EYST photocatalyst, UV-visible-light was irradiated using a tapered UV optical array. Thereafter, to eliminate the effect of temperature on the device, a FBG sensor as a temperature-compensating element was presented. To demonstrate the sensitivity and selectivity of the proposed device, we investigated the effects of the EYST coating's thickness, phenol-based analytes and temperature on the sensitivity and accuracy of the device for measuring phenol concentrations. The results of our present study suggest that the photochemical sensor is effective over a wide range of concentrations (7.5 μg L-1 to 100 mg L-1), pH values (2.0 to 14.0), and temperatures (10 to 48 °C) for selective detection of phenol in aqueous solutions. Thus, the proposed lab-on-a-chip device may be useful for accurate determination of phenol concentrations in real samples.
Related Concept Videos
Chemical Reactions in Aqueous Solutions
Aqueous Solutions and Heats of Hydration
When ionic compounds dissolve in water, the ions in the solid separate and disperse uniformly throughout the solution because water molecules surround and solvate the ions, reducing the strong electrostatic forces between them. This process...
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):
General Properties of Solutions
Solution Formation
This selective...
Ideal Solutions

