Related Experiment Video
Updated: Feb 10, 2026

Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Arsenic Trioxide-Coated Stent Is an Endothelium-Friendly Drug Eluting Stent
Yinping Zhao1, Ruolin Du1, Tian Zhou1
1Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing, 400030, China.
Abstract:
An ideal vascular stent would both inhibit in-stent restenosis (ISR) and promote rapid re-endothelialization. In the current study, the performance of arsenic trioxide (ATO)-drug eluting stent (AES) is compared with the bare metal stent, poly-lactic-co-glycolic acid-coating metal stent, and rapamycin-drug eluting stent (RES). In vivo AES is shown to prevent neointimal hyperplasia more efficiently than the others when implanted into the carotid arteries of rabbits. Moreover, AES promotes endothelial cells proliferation and re-endothelialization more quickly than RES. In vitro ATO exposure significantly increases the viability, proliferation, adhesion, and spreading of primary porcine coronary artery endothelial cells (PCAECs), which are critical for endothelialization. However, ATO exposure reduces the viability of porcine coronary artery smooth muscle cells (PCASMCs). The evaluation of mitochondrial morphology, membrane potential, and function demonstrates that ATO at 2 µmol L-1 causes enlargement of the mitochondrion, enhancement of mitochondrial membrane potential, and adenosine triphosphate (ATP) production in PCAECs but not in PCASMCs. Thus, both in vivo and in vitro studies demonstrate that AES is an effective strategy for rapid re-endothelialization and inhibition of ISR.
More Related Videos
05:37Human Internal Mammary Artery IMA Transplantation and Stenting: A Human Model to Study the Development of In-Stent Restenosis
Published on: May 9, 2012
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Pinching-off of Coated Vesicles
Clathrin Coated Vesicles
COP Coated Vesicles
Coat Assembly and GTPases
Coat assembly depends on the local availability of phosphatidylinositol phosphates or PIPs and GTP-binding proteins. Adaptor proteins, which link the coat proteins to the membrane, bind to these PIPs and play a crucial role in controlling...
Pharmacokinetics: Drug–Drug Interactions