Custom air puff-derived biomechanical variables in a refractive surgery screening setting: Study from 2 centers
Related Experiment Video
Updated: Feb 10, 2026

Subjective Refraction Test Using a Smartphone for Vision Screening
Published on: October 18, 2024
Vinicius S De Stefano1, Ibrahim Seven1, J Bradley Randleman1
1From the Cole Eye Institute (De Stefano, Seven, Dupps) and the Department of Biomedical Engineering (Dupps), Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, and the Keck School of Medicine (Randleman) and the Roski Eye Institute (Randleman), University of Southern California Los Angeles, Los Angeles, California, USA; Ophthalmology (De Stefano), Federal University of São Paulo, São Paulo, Brazil.
Purpose:
To assess the ability of air puff-derived biomechanical variables to predict surgeon-perceived candidacy for laser in situ keratomileusis (LASIK).
Setting:
Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio, and Emory Eye Institute, Emory University, Atlanta, Georgia, USA.
Design:
Retrospective case series.
Methods:
Data were collected from refractive surgery screening examinations by 2 surgeons at 2 centers. Disqualified cases (19 eyes and 28 eyes from each surgeon) were judged not to be candidates based on available data including standard variables from the Ocular Response Analyzer. Controls consisted of LASIK candidates (n = 26 and 23). Three custom biomechanical variables not available during screening were calculated and compared by group and surgeon.
Results:
The hysteresis loop area was significantly different between disqualified cases and controls for both surgeons (Surgeon 1: controls, 121.50 ± 25.38 [SD], disqualified, 107.62 ± 18.50, P = .04; Surgeon 2: controls, 135.89 ± 22.47, disqualified, 106.11 ± 16.40, P < .001). The area under the curves of the receiver operating characteristics and the cutoff values were statistically significant for the concavity minimum and hysteresis loop area for Surgeon 1 and for all variables except concavity minimum for Surgeon 2. The hysteresis loop area had the highest odds ratio (Surgeon 1, 4.48, Surgeon 2, 20.00). Adjusted R2 in best-subsets regressions were 40.2% for Surgeon 1 and 62.9% for Surgeon 2.
Conclusions:
The hysteresis loop area was predictive of which patients were disqualified for LASIK at different sites. Certain measures of the corneal dynamic response to an air puff might serve as correlates to clinically perceived ectasia risk.
Related Concept Videos
Specialized Care Centers and Settings-I
Daycare centers
They provide several functions. Some facilities care for healthy newborns and children whose parents work, while others are medically focused and care for...
Specialized Care Centers and Settings-II
Rural health centers are specialized care facilities in remote locations with very few medical personnel. The primary care providers who run the centers are mostly Registered Nurse Practitioners. Here, emergency treatment is provided to critically ill or injured patients before they are transferred to the closest hospital. Fortunately, due to advancement in technology, many rural healthcare facilities and professionals have easy access to diagnostic and treatment...
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...