Related Experiment Video
Updated: Feb 10, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Long-term Schneiderian membrane thickness changes following zygomatic implant placement: A retrospective radiographic
Kai Zhao1, Meifei Lian2, Shengchi Fan1
1Second Dental Clinic, Department of Oral Implantology, Shanghai Key Laboratory of Stomatology, Ninth People's Hospital, Shanghai Jiao Tong University, School of Medicine, National Clinical Research Center of Stomatology, Shanghai, China.
Objectives:
The purpose of this retrospective study was to evaluate the long-term changes in the thickness of Schneiderian membranes after zygomatic implant placement using cone beam computed tomography (CBCT).
Material And Methods:
Twenty-five consecutive patients were included in this study. All the patients underwent bilateral zygomatic implant placement. Schneiderian membrane thickness (SMT) in 49 maxillary sinuses (one sinus was not included because of early loss of the zygomatic implants) was measured using CBCT before and at least 1 year after zygomatic implant placement. Ostium patency of each sinus was also evaluated and recorded.
Results:
In total, 84 zygomatic implants and 30 regular implants were placed in included patients. Two unilateral maxillary zygomatic implants in one patient were removed 2 months after implant placement. The SMT increased from 1.03 mm (inter-quartile range: 1.57 mm) to 1.33 mm (inter-quartile range: 1.98 mm) after a median follow-up time of 23.00 months (inter-quartile range: 14 months), and the difference was statistically significant. Before zygomatic implant insertion, 24.5% (12/49) of sinuses had SMT greater than 2 mm, whereas this value was 28.6% (14/49) after zygomatic implant placement. The percentage of sinuses observed with ostium patency also increased from 2.0% (1/49) to 12.2% (6/49).
Conclusions:
Chronic Schneiderian membrane thickening could result from zygomatic implant insertion. Intensive postoperative care and clinical and radiographic monitoring are recommended after zygomatic implant placement.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Long-term Depression
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...

