Related Experiment Video
Updated: Feb 10, 2026

A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Optimization and Validation of an Analytical Method for the Determination of Some Trace and Toxic Elements in Canned
Mahmoud M Ghuniem1, Mona A Korshed2, Eglal R Souaya3
1Lr:16084152.
Abstract:
Background: There is increasing concern about the health effects on humans due to continuous consumption of fruit juices contaminated with metals. Objective: Quadrupole inductively coupled mass spectrometry (Q-ICP-MS) was optimized, validated, and applied in routine analysis for determination of As, Pb, Cd, Sb, Hg, Cu, Zn, Fe, Al, Cr, Sn, Co, Mn, and Ni in fruit juice beverages. Methods: Several validation parameters, such as detection limits (DLs), quantification limits, linearity, accuracy, and measurement uncertainty (MU), were studied under optimized Q-ICP-MS conditions. Results: The method showed that the DLs varied between 0.986 and 68.691 μg/kg, and the quantification limits varied between 20 μg/kg and 0.5 mg/kg. The mean recoveries ± SDs at different spiking levels varied between 74.87 ± 1.03 and 117.61 ± 1.74%. The method trueness was confirmed by using four different certified reference fruit juices purchased from Fapas, and all obtained results were within satisfactory ranges and had acceptable z-score values. The method precision, in terms of relative standard deviation, was below 4.38%. The method uncertainty expressed as expanded uncertainty was found to be ≤21.25%. Conclusions: The results obtained make the method suitable for a precise and accurate determination of these chemical elements in fruit juice beverages at low concentration values. Highlights: A Q-ICP-MS method for element determination in juices was optimized and validated. Validation was based on DL, quantification limits, linearity, accuracy, and MU. Fourteen elements were identified in the validated method.
More Related Videos
09:05Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
08:46Dose Uptake of Platinum- and Ruthenium-based Compound Exposure in Zebrafish by Inductively Coupled Plasma Mass Spectrometry with Broader Applications
Published on: April 21, 2022
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometers
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Development of Analytical Methods