Related Experiment Video
Updated: Feb 10, 2026

Cerenkov Luminescence Imaging CLI for Cancer Therapy Monitoring
Published on: November 13, 2012
How to better monitor and clean irregular surfaces in operating rooms: Insights gained by using both ATP luminescence
Olivia Ellis1, Hilary Godwin2, Maren David3
1UCLA Fielding School of Public Health, Department of Environmental Health Sciences, Los Angeles, CA.
Background:
A major limitation to developing evidence-based approaches to infection prevention is the paucity of real-time, quantitative methods for monitoring the cleanliness of environmental surfaces in clinical settings. One solution that has been proposed is adenosine triphosphate (ATP) bioluminescence assays, but this method does not provide information about the source of the ATP.
Materials/Methods:
To address this gap, we conducted a study in which ATP bioluminescence was coupled with traditional RODAC sampling and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry to assess which organisms were viable and present. Using this mixed assessment approach, we evaluated cleaning of 5 different types of high-touch surfaces (overhead lights, door handles, anesthesia keyboards, mattresses, and side tables) in operating rooms.
Results:
Whether surfaces tested cleaner after turnaround than they did before turnaround depended on the surface type. Before and after cleaning, flat, covered surfaces (mattresses and side tables) were more likely to pass as "clean" by ATP assay than uncovered, irregularly shaped surfaces (overhead lights, door handles, and anesthesia keyboards). Irregularly shaped surfaces were more likely to pass by RODAC assay than by ATP assay after cleaning.
Conclusion:
Our results suggest that irregularly shaped surfaces in operating rooms may require enhanced covering, cleaning, and monitoring protocols compared to more regularly shaped surfaces.
Related Concept Videos
Areas Within Irregular Boundaries
ATP Yield
The ETC is embedded in the inner mitochondrial membrane and is comprised of four main protein complexes and an ATP synthase. NADH and FADH2 pass electrons to these complexes, which pump protons into the intermembrane space. This distribution of...
Hydrolysis of ATP
If one phosphate group is removed, a molecule of ADP—adenosine diphosphate—remains, along with inorganic phosphate. ADP can be further hydrolyzed to AMP—adenosine...
Gain
Gain:
Suppose Vin is the input and Vout is the output signal to a circuit.
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
ATP Synthase: Mechanism