Related Experiment Video
Updated: Feb 10, 2026

A Strategy for Sensitive, Large Scale Quantitative Metabolomics
Published on: May 27, 2014
A sensitive calorimetric technique to study energy (heat) exchange at the nano-scale
Luca Basta1, Stefano Veronesi, Yuya Murata
1NEST, Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza S. Silvestro 12, 56127 Pisa, Italy. luca.basta1@sns.it stefano.veronesi@nano.cnr.it.
Abstract:
Every time a chemical reaction occurs, an energy exchange between reactants and the environment takes place, which is defined as the enthalpy of the reaction. During the last few decades, research has resulted in an increasing number of devices at the micro- or nano-scale. Sensors, catalyzers, and energy storage systems are more and more developed as nano-devices which represent the building blocks for commercial "macroscopic" objects. A general method for the direct evaluation of the energy balance of such systems is not available at present. Calorimetry is a powerful tool to investigate energy exchange, but it usually requires macroscopic sample quantities. Here, we report on the development of an original experimental setup able to detect temperature variations as low as 10 mK in a sample of ∼10 ng using a thermometer device having physical dimensions of 5 × 5 mm2. This technique has been utilized to measure the enthalpy release during the adsorption process of H2 on titanium-decorated monolayer graphene. The sensitivity of these thermometers is high enough to detect a hydrogen uptake of ∼10-10 moles, corresponding to ∼0.2 ng, with an enthalpy release of about 23 μJ. The experimental setup allows, in perspective, scalability to even smaller sizes.
Related Concept Videos
Energy Basics
Quantifying Heat
Internal Energy
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...

