Background:
Placing a self-expandable metallic stent (SEMS) is safe and effective for the palliative treatment of malignant gastroduodenal (GD) strictures. SEMS abutment in the duodenal wall is associated with increased food impaction, resulting in higher stent malfunction and shorter stent patency. The desire to evaluate the mechanism and significance of stent abutment led us to design an in vitro experiment using a flexible anthropomorphic three-dimensional (3D)-printed GD phantom model.
Results:
A GD phantom was fabricated using 3D printer data after performing computed tomography gastrography. A partially covered (PC) or fully covered (FC) stent was placed so that its distal end abutted onto the duodenal wall in groups PC-1 and FC-1 or its distal end was sufficiently directed caudally in groups PC-2 and FC-2. The elapsed times of the inflowing of three diets (liquid, soft, and solid) were measured in the GD phantom under fluoroscopic guidance. There was no significant difference in the mean elapsed times for the liquid diet among the four groups. For the soft diet, the mean elapsed times in groups PC-1 and FC-1 were longer than those in groups PC-2 and FC-2 (P = 0.018 and P < 0.001, respectively). For the solid diet, the mean elapsed time in group PC-1 was longer than that in group PC-2 (P < 0.001). The solid diet could not pass in group FC-1 due to food impaction. The mean elapsed times were significantly longer in groups FC-1 and FC-2 than in groups PC-1 and PC-2 for soft and solid diets (all P < 0.001).
Conclusions:
This flexible anthropomorphic 3D-printed GD phantom study revealed that stent abutment can cause prolonged passage of soft and solid diets through the stent as well as impaction of solid diets into the stent.
More Related Videos
05:37Human Internal Mammary Artery IMA Transplantation and Stenting: A Human Model to Study the Development of In-Stent Restenosis
Published on: May 9, 2012
06:55Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
Related Concept Videos
Gastric Motility
Peristaltic Waves and Chyme Formation
Upon food entry, the stomach initiates...
Gastric Emptying
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Gastric Phase of Digestion
When food enters the stomach, it stretches the stomach walls and activates stretch receptors. This triggers local reflexes of the enteric nervous system, mediated through the myenteric plexus. These...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Design Example: Measuring Distance Between Two Points with Obstructions