Related Experiment Video
Updated: Feb 10, 2026

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher
Published on: February 23, 2018
Effects of Scleral-lens Tear Clearance on Corneal Edema and Post-lens Tear Dynamics: A Pilot Study
Bo Tan1, Yixiu Zhou1, Tiffany L Yuen1
1Clinical Research Center, School of Optometry, University of California, Berkeley, Berkeley, California.
Significance:
The present study with small-diameter scleral lenses (SLs) revealed that post-lens tear thickness (PoLTT) was significantly associated with post-lens tear mixing, but not with central corneal edema, after short-term SL wear.
Purpose:
The aim of this study was to investigate the influence of SL tear clearance (PoLTT) on central corneal thickness and post-lens tear dynamics during 5-hour lens wear.
Methods:
Neophytes with no active ocular disease were fitted bilaterally with SLs (hofocon A; 15.6-mm diameter; ~438-μm thickness; 97 Dk; 1.44 refractive index) with various initial PoLTT values ranging from 74 to 543 μm. Central corneal thickness and PoLTT were measured using optical coherence tomography during lens wear. Tear mixing was assessed using fluorogram and "out-in" method.
Results:
The mean central corneal edema after 5-hour lens wear was 1.51% (95% confidence interval, 1.26 to 1.76%; P < .001), reached its peak at 2-hour post-lens insertion (1.65% [95% confidence interval, 1.45 to 1.85%]), and was independent of PoLTT. The fastest fluorescence decay of the post-lens tear film was observed superiorly. The fluorescence decay rate increased from center to periphery in all quadrants except superiorly. An inverse relationship was found between PoLTT and fluorescence decay rate at both 20-minute and 5-hour wear after lens insertion (P < .05). Excluding observations with out-in time exceeding 5 minutes, we found a direct relationship between PoLTT at 20 minutes after lens insertion and out-in time (P = .047). The % change in the PoLTT after 5-hour wear was greater with a thinner initial tear clearance than those with a thicker one (P = .034).
Conclusions:
Within our study parameters, a thinner PoLTT under a small-diameter SL was associated with faster PoLTT mixing. However, there was no relationship between PoLTT and central corneal thickness during 5-hour SL wear.
Related Concept Videos
Pilot and Numeric Relaying
Hepatic Drug Clearance: Restrictive and Nonrestrictive Clearance
Most drugs undergo restrictive clearance, which is proportional to the...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Clearance: Overview
Drug clearance is not limited to renal excretion but encompasses all organs involved in drug elimination, including...
Dynamic Equilibrium
Clearance Models: Physiological Models
The organ's clearance rate depends on the blood flow to the organ and the extraction ratio (E). The extraction ratio describes the organ's...