Related Experiment Video
Updated: Feb 10, 2026

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher
Published on: February 23, 2018
Clinical Performance of a New Bitangential Mini-scleral Lens
Henny M Otten, Bart J J J van der Linden1, Esther-Simone Visser2
1NKL Contactlenzen, Emmen, The Netherlands *hon@vissercontactlenzen.nl.
Significance:
New bitangential mini-scleral lens designs provide a highly precise fit, follow the scleral shape, are comfortable to wear, and can correct residual astigmatism. This new scleral lens design complements the arsenal of medical contact lenses available to eye care practitioners.
Purpose:
The aim of this study was to evaluate the subjective and objective performance of a new mini-scleral lens design with a bitangential periphery.
Methods:
In this observational study, data were collected for up to 15 months (median, 84 days; interquartile range, 76 days) from the left eyes of 133 patients fitted with this newly designed lens. Data were recorded during regular visits at Visser Contact Lens Practice's scleral lens clinics: diagnosis, clinical indication for scleral lenses, previous contact lens type, subjective performance, horizontal visible iris diameter, corrected distance visual acuity, and scleral lens fitting characteristics.
Results:
The most common indication was keratoconus (45%), followed by irregular astigmatism (22%), keratoplasty (16.5%), ocular surface disease (13.5%), and other forms of irregular astigmatism (3%). The majority of patients (79%) scored comfort as either a 4 or 5 (out of 5), and 82% wore their lenses 12 hours or longer a day. Most lenses (81%) had a diameter of 16 mm (median, 16 mm; range, 15.5 to 17 mm) and were composed of Boston XO2 (46%), Menicon Z (44%), Boston XO (9%), or Boston Equalens II (1%). The median corrected distance visual acuity was 0.022 logarithm of the minimal angle of resolution (interquartile range, 0.155). The fitting characteristics revealed optimal values for centration and movement in 91% and 83%, respectively. Finally, the median stabilization axis was 50 degrees.
Conclusions:
New mini-scleral lenses with bitangential peripheral geometry yield satisfactory clinical results and good subjective performance and are therefore an effective option for managing patients who have irregular astigmatism or other corneal pathology.
More Related Videos
09:03Generating Spheroids from Various Chondrocytes using Low-Adhesive Conditions under Gravity and Homemade Mini-Bioreactors
Published on: January 31, 2025
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
Related Concept Videos
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Clinical Trials
There are four phases in a clinical trial. A phase one...
Pathophysiology of Cardiac Performance
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Clinical Trials: Overview
Sources of Self-Esteem II: Performance Feedback