Related Experiment Video
Updated: Feb 10, 2026

Acute and Chronic Tactile Sensory Testing after Spinal Cord Injury in Rats
Published on: April 4, 2012
Validation of predictive equations to assess energy expenditure in acute spinal cord injury
Christine L Ramirez1, Stacy Pelekhaty, Jennifer M Massetti
1From the St. Luke's University Health Network, Bethlehem, Pennsylvania; and R Adams Cowley Shock Trauma Center (C.L.R., S.P., J.M.M., S.G., L.H., I.B., T.M.S., D.M.S.), Baltimore, Maryland.
Background:
Acute spinal cord injury (SCI) is devastating with morbidities compounded by inadequate nutrition. The American Society for Parenteral and Enteral Nutrition recommends indirect calorimetry (IC) to evaluate energy needs in SCI because no predictive energy equations have been validated. We sought to determine the accuracy of predictive equations to predict measured energy expenditure (MEE).
Methods:
A retrospective review was performed over 2 years. Patients 18 years or older with cervical SCI who received IC were included. Height, weight, maximum temperature and minute ventilation on day of IC, plus MEE and VCO2 from IC were obtained. Predicted energy expenditure (PEE) was calculated using Harris-Benedict (HB), Penn State (PS), Mifflin St. Jeor (MSJ), Weir, Ireton-Jones (IJ), and 25 kcal/kg formulas. MEE was then compared to the PEE of each method.
Results:
Thirty-nine IC studies were completed for 20 patients. Weir had the strongest correlation to MEE (r = 0.98), followed by PS (r = 0.82). Correlations were similar among HB (r = 0.78), MSJ (r = 0.75), and IJ (r = 0.73), and weakest with 24 kcal/kg (r = 0.55). All had a p value <0.001. Deming regression confirmed strong correlations between Weir and PS to MEE, with coefficients of 1.03 and 1.515 (p < 0.001), respectively. Other formulas had comparatively higher coefficients and standard errors. Bland-Altman analysis confirmed Weir had the narrowest range of difference, with a mean difference of 25.5 kcal/day, followed by PS (-336.1 kcal/day).
Conclusions:
Weir is the best predictive energy equation, with all statistical tests demonstrating a strong correlation between MEE and Weir. The second best predictive equation is the Penn State formula, which predicts actual MEE measured by IC with high accuracy.
Level Of Evidence:
Diagnostic study, level III.
Related Concept Videos
Spinal Cord
The Spinal Cord
Spinal Cord: Information Processing
Sensory Information Processing
Sensory information processing begins at the sensory receptors located in the skin and other tissues, which detect somatic sensory stimuli such as touch, temperature, or pain. These receptors function as catalysts, initiating...
Application of the Energy Equation
The Nernst Equation
The interconnection between standard cell potentials and various thermodynamic parameters such as the standard free energy change ΔG° and equilibrium constant K has been previously explored. For example, a redox reaction involving zinc(II) and tin(II) ions at 1 M concentration with Eºcell = +0.291 V and ΔG° = −56.2 kJ is spontaneous.
Energy Conservation and Bernoulli's Equation
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...

