Related Experiment Video
Updated: Feb 10, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Efficacy and safety of transcatheter valve-in-valve replacement for Mitroflow bioprosthetic valve dysfunction
Victor X Mosquera1, Miguel González-Barbeito1, Alberto Bouzas-Mosquera2
1Department of Cardiac Surgery, Complejo Hospitalario Universitario de A Coruña, A Coruña, Spain.
Objectives:
Bioprostheses with pericardial leaflets mounted externally on the stent pose a high risk for valve-in-valve (ViV) procedures. This study analyzed the efficacy and safety of ViV procedures for treating structural valve deterioration (SVD) in Mitroflow bioprostheses.
Methods:
Between January 2012 and August 2017, 11 patients (mean age 80.3 ± 5.6 years) were treated for SVD of Mitroflow bioprostheses with transcatheter ViV procedures (six transapical [TA] and five transfemoral [TF]) using balloon expandable bioprostheses.
Results:
All patients but one were in NYHA class III-IV. Mean STS PROM, euroSCORE I, and euroSCORE II were 8 ± 6.5%, 27.8 ± 11.5%, and 12 ± 5.9%, respectively. Two patients had a "porcelain aorta." The size of implanted valves were 23 mm in 10 cases and 26 mm in one case. One patient suffered a coronary occlusion during a TF approach. The mean volume of contrast used in TF implants was 163 ± 69.8 mL. No contrast media were used in TA procedures. There was one in-hospital death (10%). At 1 year of follow-up, peak and mean aortic gradients were 25.5 ± 5.8 mmHg and 15.5 ± 5.7 mmHg, respectively. One patient had mild paravalvular regurgitation. Cumulative survival was 90.9% at 1 year, 70.7% at 2 years, and 53% at 3 years.
Conclusions:
ViV procedures with balloon-expandable aortic valves provide good hemodynamic and clinical mid-term results for treating patients with a degenerated Mitroflow aortic bioprosthesis. Special care must be taken in small aortic roots, when the stented valve is in the supra-annular position to avoid coronary ostial obstruction.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Survey Safety
Self-Efficacy