Related Experiment Video
Updated: Feb 10, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Is the cup orientation different in bilateral total hip arthroplasty with right-handed surgeons using posterolateral
Xinggui Song1,2, Ming Ni1, Heng Li1
1Orthopaedic Department, Chinese PLA General Hospital, 28 Fuxing Road, Haidian District, Beijing, People's Republic of China.
Background:
The impact of surgeon handedness on acetabular cup orientation in total hip arthroplasty (THA) is not well studied. The aim of our study is to investigate the difference of cup orientation in bilateral THA performed by right-handed surgeons using posterolateral approach and which cup could be fitter to Lewinneck's safe zone.
Methods:
The study consisted of 498 patients that underwent bilateral THA by three right-handed surgeons in our hospital. Postoperative acetabular cup anteversion and abduction on an anteroposterior pelvic radiograph were measured by Orthoview software (Orthoview LLC, Jacksonville, Florida). Furthermore, the percentage of cup placement within the safe zone was compared.
Results:
The mean anteversion was 25.28 (25.28° ± 7.16°) in left THA and 22.01 (22.01° ± 6.35°) in right THA (p < 0.001). The mean abduction was 37.50 (37.50° ± 6.76°) in left THA and 38.59 (38.59° ± 6.84°) in right THA (p = 0.011). In the left side, the cup was positioned in Lewinnek's safe zone in 52% for anteversion, 87% for abduction, and 46% for both anteversion and abduction. But the cup placement within Lewinnek's safe zone was 71, 88, and 62% in the right side, respectively. There were significant differences in the percentage of acetabular cup placement within the safe zone for anteversion (p < 0.001) and for both anteversion and inclination (p < 0.001). Dislocation occurred in 7.0% (35/498) of cases in left THA and 3.2% (16/498) in right THA. The percentages of patients experiencing dislocation were significantly different between the two sides (p = 0.006).
Conclusions:
This current study demonstrated that surgeon handedness is likely to be a contributing factor that affects cup inclination and anteversion in bilateral THA and that the placement of cup performed by dominant hands of surgeons is more accurate than that performed by non-dominant sides.
Related Concept Videos
Hand hygiene
Hand washing...
Location and Orientation of the Heart
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
Total Voids in Concrete

