Related Experiment Video
Updated: Feb 10, 2026

Computerized Adaptive Testing System of Functional Assessment of Stroke
Published on: January 7, 2019
a-Stratified Computerized Adaptive Testing in the Presence of Calibration Error
Ying Cheng1, Jeffrey M Patton1, Can Shao1
1University of Notre Dame, Notre Dame, IN, USA.
Abstract:
a-Stratified computerized adaptive testing with b-blocking (AST), as an alternative to the widely used maximum Fisher information (MFI) item selection method, can effectively balance item pool usage while providing accurate latent trait estimates in computerized adaptive testing (CAT). However, previous comparisons of these methods have treated item parameter estimates as if they are the true population parameter values. Consequently, capitalization on chance may occur. In this article, we examined the performance of the AST method under more realistic conditions where item parameter estimates instead of true parameter values are used in the CAT. Its performance was compared against that of the MFI method when the latter is used in conjunction with Sympson-Hetter or randomesque exposure control. Results indicate that the MFI method, even when combined with exposure control, is susceptible to capitalization on chance. This is particularly true when the calibration sample size is small. On the other hand, AST is more robust to capitalization on chance. Consistent with previous investigations using true item parameter values, AST yields much more balanced item pool usage, with a small loss in the precision of latent trait estimates. The loss is negligible when the test is as long as 40 items.
More Related Videos
09:00Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education
Published on: August 16, 2024
10:10Evaluating Tests of Cognition using a Computerized Touch-Sensitive Tablet, Eye Tracking, and Functional Magnetic Resonance Imaging
Published on: January 30, 2026
Related Concept Videos
Errors In Hypothesis Tests
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...
Stratified Sampling Method
To choose a stratified sample, divide the population into groups called strata and then take a...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...