ICD lead type and RV lead position in CRT-D recipients
Alexander P Benz1, Mate Vamos1, Julia W Erath1
1Division Clinical Electrophysiology, Department of Cardiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590, Frankfurt am Main, Germany.
Background:
Data on preferred ICD lead type and optimal RV lead position in patients undergoing CRT-D implantation are limited.
Objectives:
To compare dual- versus single-coil ICD leads and non-apical versus apical RV lead position and their impact on clinical parameters and survival in CRT-D recipients.
Methods:
A total of 563 consecutive patients with advanced heart failure and indication for CRT-D implantation were enrolled in two European tertiary centers. Endpoints were improvement in NYHA functional class, changes in echo- and electrocardiographic parameters, and all-cause and cardiovascular mortality.
Results:
In this retrospective analysis, a total of 313 (56%) dual- and 250 (44%) single-coil ICD leads were used. RV leads were placed non-apically in 262 (47%) and apically in 296 (53%) patients, respectively. Over a mean follow-up of 41 ± 34 months, all-cause mortality and cardiovascular mortality were similar for patients with dual- versus single-coil ICD lead (adjusted HR 0.81, 95% CI 0.58-1.12 and aHR 1.22, 95% CI 0.73-2.04) and non-apical versus apical RV lead position (aHR 0.98, 95% CI 0.71-1.36 and aHR 0.76, 95% CI 0.44-1.31). Non-apical RV lead position was associated with greater reduction in QRS duration after CRT implantation (- 14.4 ± 32.1 vs. - 4.3 ± 34.3 ms, p < 0.001).
Conclusions:
We found no association between ICD lead type or RV lead position and outcomes in CRT-D recipients. Non-apical RV lead position was associated with larger reduction in QRS duration.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Types of Global Positioning System Surveys
Chromatin Position Affects Gene Expression
Topologically Associated Domains (TADs)
The 3-dimensional positioning of chromatin in the nucleus influences the...
Position-effect Variegation
Types of Chemical Bonds