Related Experiment Video
Updated: Feb 10, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Peri-anal surface dose in anal canal VMAT radiotherapy
Kurian Joseph1, Brenda Rose2, Heather Warkentin3
1Division of Radiation Oncology, Department of Oncology, University of Alberta & Cross Cancer Institute, Edmonton, Alberta, Canada.
Introduction:
Skin bolus may routinely be used in the perineum to build up the surface dose in the treatment of anal cancer (ACC); this may contribute to significant acute skin toxicity. Skin bolus may not be needed with the introduction of modern radiotherapy techniques if these planning techniques would achieve adequate surface dose. Our study is to ascertain if appropriate skin dose can be achieved without the use of bolus when VMAT is used in the treatment of ACC.
Methods:
The study includes 10 ACC patients treated with VMAT radiotherapy. Optically stimulated luminescence dosimeters (OSLD) are used to evaluate whether the calculated dose for the VMAT planning technique (VMAT-PT) accurately predicted the dose delivered to peri-anal target region without bolus. The OSLD recorded the dose at the anal verge or at the lower most extent of the tumour for each patient over two fractions. The OSLD was read after each of the two fractions, and the average value was reported. The mean dose over a volume centred on the anal marker was calculated in the treatment planning system (TPS).
Results:
The mean TPS-calculated dose was 186.1 cGy. The mean of the OSLD-measured doses was 205.7 cGy for a single fraction. The mean of the measured doses was 10.6% higher than the mean of the calculated doses.
Conclusions:
The calculated dose for the VMAT-PT consistently under-predicted the dose delivered to the peri-anal target region without bolus. Routine use of skin bolus could be avoided with VMAT-PT when the patient is treated in a supine position.
Related Concept Videos
Psychosexual Stages of Personality: Anal
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Drug Dosing: Infants and Children
Drug Dosing: Geriatric Patients