Biomechanical Robustness of a Contemporary Cementless Stem to Surgical Variation in Stem Size and Position
Rami M A Al-Dirini1, Dermot O'Rourke2, Daniel Huff3
1Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5043, Australia e-mail: .
Abstract:
Successful designs of total hip replacement (THR) need to be robust to surgical variation in sizing and positioning of the femoral stem. This study presents an automated method for comprehensive evaluation of the potential impact of surgical variability in sizing and positioning on the primary stability of a contemporary cementless femoral stem (Corail®, DePuy Synthes). A patient-specific finite element (FE) model of a femur was generated from computed tomography (CT) images from a female donor. An automated algorithm was developed to span the plausible surgical envelope of implant positions constrained by the inner cortical boundary. The analysis was performed on four stem sizes: oversized, ideal (nominal) sized, and undersized by up to two stem sizes. For each size, Latin hypercube sampling was used to generate models for 100 unique alignment scenarios. For each scenario, peak hip contact and muscle forces published for stair climbing were scaled to the donor's body weight and applied to the model. The risk of implant loosening was assessed by comparing the bone-implant micromotion/strains to thresholds (150 μm and 7000 με) above which fibrous tissue is expected to prevail and the periprosthetic bone to yield, respectively. The risk of long-term loosening due to adverse bone resorption was assessed using bone adaptation theory. The range of implant positions generated effectively spanned the available intracortical space. The Corail stem was found stable and robust to changes in size and position, with the majority of the bone-implant interface undergoing micromotion and interfacial strains that are well below 150 μm and 7000 με, respectively. Nevertheless, the range of implant positions generated caused an increase of up to 50% in peak micromotion and up to 25% in interfacial strains, particularly for retroverted stems placed in a medial position.
Related Concept Videos
Adult Stem Cells
Embryonic Stem Cells
Embryonic Stem Cells
ES cells are grown in a culture medium where they can divide indefinitely, creating ES cell lines. Under certain conditions, ES cells can differentiate, either spontaneously into a variety of...
Induced Pluripotent Stem Cells
Contemporary Psychology
Biopsychology
Biopsychology, also known as biological psychology or behavioral neuroscience, focuses on the biological underpinnings of behavior and mental processes. It...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...