Effect of Selective Antibiotic Pressure on the MLS-B Phenotype in Methicillin-Resistant Staphylococcus aureus Strains

K Szymanek-Majchrzak1, A Mlynarczyk2, M Bilinska3

  • 1Department of Medical Microbiology, Medical University of Warsaw, Warsaw, Poland; Department of Medical Microbiology, The Infant Jesus Teaching Hospital, Warsaw, Poland.

Abstract

Insights

Antibiotic resistance in health care-associated-methicillin resistant Staphylococcus aureus (HA-MRSA) is linked to clindamycin use. Reducing antibiotic selection pressure can decrease resistance, potentially restoring inductive resistance mechanisms.

Area of Science:

  • Medical Microbiology
  • Infectious Diseases
  • Antimicrobial Resistance

Background:

  • Health care-associated-methicillin resistant Staphylococcus aureus (HA-MRSA) poses a significant threat to transplant patients.
  • Combined resistance to macrolides, lincosamides, and streptogramin-B (MLS-B) antibiotics limits therapeutic options.

Purpose of the Study:

  • To investigate the mechanisms of MLS-B resistance in HA-MRSA strains from surgical-transplantation wards over 24 years.
  • To assess the correlation between clindamycin usage and the prevalence of specific resistance phenotypes.

Main Methods:

  • Analysis of 112 HA-MRSA strains collected between 1991 and 2014.
  • Phenotypic and genetic detection of methicillin resistance (mecA gene).
  • E-test and D-test methods to determine erythromycin/clindamycin resistance and MLS-B phenotypes (iMLS-B, cMLS-B).
  • Calculation of defined daily doses (DDD) per 1000 person-days for clindamycin.

Main Results:

  • Erythromycin/clindamycin resistance in MRSA increased significantly from 1991 to 2004-2007.
  • The constitutive MLS-B (cMLS-B) phenotype frequency rose from 5.9% in 1991 to 76.9% in 2010-2011, correlating with increased clindamycin use.
  • In 2012, a decrease in cMLS-B (to 69.7%) and an increase in MLS-B-sensitive isolates (to 21.7%) coincided with reduced clindamycin usage.

Conclusions:

  • The prevalence of cMLS-B versus iMLS-B phenotypes in HA-MRSA is directly influenced by clindamycin consumption in hospital settings.
  • Decreasing antibiotic selection pressure can lead to the loss of resistance or a shift back to inducible resistance mechanisms.

Related Concept Videos

Antibiotic Selection00:57

Antibiotic Selection

Overview
60.1K
Development of Antibiotic Resistance01:30

Development of Antibiotic Resistance

Antibiotic resistance is a major public health concern that arises when bacteria evolve mechanisms to withstand the effects of antibiotic treatments. This resistance can be intrinsic, acquired through genetic mutations, or transferred between bacteria via horizontal gene transfer. The development of antibiotic resistance poses significant challenges in treating bacterial infections and necessitates ongoing research to develop new therapeutic strategies.Intrinsic resistance occurs when bacterial...
1.5K
Frequency-dependent Selection01:21

Frequency-dependent Selection

When the fitness of a trait is influenced by how common it is (i.e., its frequency) relative to different traits within a population, this is referred to as frequency-dependent selection. Frequency-dependent selection may occur between species or within a single species. This type of selection can either be positive—with more common phenotypes having higher fitness—or negative, with rarer phenotypes conferring increased fitness.
24.2K
Naturalistic Observations02:30

Naturalistic Observations

If you want to understand how behavior occurs, one of the best ways to gain information is to simply observe the behavior in its natural context. However, people might change their behavior in unexpected ways if they know they are being observed. How do researchers obtain accurate information when people tend to hide their natural behavior? As an example, imagine that your professor asks everyone in your class to raise their hand if they always wash their hands after using the restroom. Chances...
17.5K
Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
2.7K
Resistivity01:22

Resistivity

When a voltage is applied to a conductor, an electrical field is generated, and charges in the conductor feel the force due to the electrical field. The current density that results depends on the electrical field and the properties of the material. In some materials, including metals at a given temperature, the current density is approximately proportional to the electrical field. In these cases, the current density can be modeled as:
4.6K