Rapid detection of viable Legionella pneumophila in tap water by a qPCR and RT-PCR-based method
R Boss1, A Baumgartner1, S Kroos2
1Federal Food Safety and Veterinary Office, Berne, Switzerland.
Aims:
A molecular method for a rapid detection of viable Legionella pneumophila of all serogroups in tap water samples was developed as an alternative to the reference method (ISO). Legionellae are responsible for Legionnaires' disease, a severe pneumonia in humans with high lethality.
Methods And Results:
The developed method is based on a nutritional stimulation and detection of an increase in precursor 16S rRNA as an indicator for viability. For quantification, DNA was detected by qPCR. This method was compared to the ISO method using water samples obtained from public sports facilities in Switzerland. The sensitivity and specificity were 91 and 97%, respectively, when testing samples for compliance with a microbiological criterion of 1000 cell equivalents per l.
Conclusion:
The new method is sensitive and specific for Leg. pneumophila and allows results to be obtained within 8 h upon arrival, compared to one week or more by the ISO method.
Significance And Impact Of The Study:
The method represents a useful tool for a rapid detection of viable Leg. pneumophila of all serogroups in water by molecular biology. It can be used as an alternative to the ISO method for official water analysis for legionellae and particularly when a short test time is required.
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Water: A Bronsted-Lowry Acid and Base
PCR
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
The Water Cycle