Related Experiment Video
Updated: Feb 10, 2026

Experiments on Ultrasonic Lubrication Using a Piezoelectrically-assisted Tribometer and Optical Profilometer
Published on: September 28, 2015
A novel single-mode linear piezoelectric ultrasonic motor based on asymmetric structure
Liang Wang1, Junkao Liu1, Yingxiang Liu1
1State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China.
Abstract:
A novel single-mode linear piezoelectric ultrasonic motor based on asymmetric structure is proposed. The motor adopts the combination of the first longitudinal vibration and the asymmetric mechanical structure to produce the oblique movement on the driving foot; then, the linear output motion is obtained under the friction coupling between the driving foot and the runner. The motor is designed and its operation principle is illustrated in detail. The transient analysis is developed to verify the formed movement on the driving foot. A prototype is manufactured and its vibration characteristics are measured by a scanning laser Doppler vibrometer. An experimental system is established and the output performances of the motor are tested and discussed. The results indicate that the maximal no-load velocity of the motor is about 127.31 mm/s under the voltage of 150 Vp-p and the preload of 30 N. The maximum thrust force is about 2.8 N when the voltage and preload are 150 Vp-p and 40 N. The related works in this paper has verified the feasibility of the proposed single-mode ultrasonic motor based on asymmetric structure.
Related Concept Videos
Principle of Linear Impulse and Momentum for a Single Particle
Delving...
Principle of Linear Impulse and Momentum for a Single Particle: Problem Solving
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
Asymmetric Lipid Bilayer
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...

