Related Experiment Video
Updated: Feb 10, 2026

Implantation of Electrospun Vascular Grafts with Optimized Structure in a Rat Model
Published on: June 27, 2018
[Study on the prevention of postoperative intraperitoneal adhesion of rat with PLGA/PEG electrospun polymer membrane]
Zaomei Chen1, Yue Zhao1, Ting He2
1Pharmaceutical college of Guangdong Pharmaceutical University, Guangzhou Guangdong, 510006, P.R.China;Department of Pharmacy, Guangzhou General Hospital of Guangzhou Military Command, Guangzhou Guangdong, 510010, P.R.China.
Objective:
Adopting poly- L-lactic/glycolic acid (PLGA) and polyethylene glycol (PEG) as the material to fabricate PLGA/PEG electrospun polymer membrane by electrospinning technology. And to study its preventive effect on postoperative intraperitoneal adhesion of rat.
Methods:
PLGA and PEG were mixed at the ratio of 19∶1( M/M), then dissolved in organic solvent. The PLGA/PEG electrospun polymer membrane was prepared by electrospinning technology, and then the gross observation and scanning electron microscope observation were taken. Fifty-four Sprague Dawley rats (weighing, 180-200 g), were randomly divided into 3 groups. The rats in control group ( n=6) were left intact. The rats in model group ( n=24) and PLGA/PEG group ( n=24) were treated with the method of mechanical injury of the cecal serosa in order to establish the intraperitoneal adhesion models; then the PLGA/PEG electrospun polymer membrane was used to cover the wound in PLGA/PEG group, but was not in the model group. The intraperitoneal adhesion in PLGA/PEG group and model group were observed at 3 days, 1 week, 2 weeks, and 8 weeks after operation, and the adhesion degree was assessed according to the self-generated standard. The degradation of PLGA/PEG electrospun polymer membrane was also observed in PLGA/PEG group. At each time point, the rats were harvested for histological observation. All the above indexes were compared with the control group.
Results:
Using the electrospinning technology, PLGA/PEG electrospun polymer membrane was prepared successfully. PLGA/PEG electrospun polymer membrane was white and opaque, with soft texture. Scanning electron microscopy observation showed that PLGA/PEG electrospun polymer membrane was mainly composed of disorderly staggered fibers, with microporous structure. All rats survived to the end of the experiment. Gross observation showed that PLGA/PEG electrospun polymer membrane gradually degraded after implantation in vivo, and the adhesion degree in PLGA/PEG group was significantly lower than that in model group ( P<0.05), but it had not yet reached to the level of the control group ( P<0.05). Histological observation showed that the proliferation of cecal fibrous connective tissue was slower in PLGA/PEG group than in model group, and adhesion severity significantly decreased, only with a small amount of inflammatory cell infiltration. Nevertheless, it was not up to the level of the control group.
Conclusion:
PLGA/PEG electrospun polymer membrane can effectively prevent postoperative intraperitoneal adhesion of rat, and has good biodegradability.
More Related Videos
06:56Particles without a Box: Brush-first Synthesis of Photodegradable PEG Star Polymers under Ambient Conditions
Published on: October 10, 2013
12:21Fabrication and Characterization of Griffithsin-modified Fiber Scaffolds for Prevention of Sexually Transmitted Infections
Published on: October 31, 2017
Related Concept Videos
Polymers
Polymers
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Cancer Prevention
Some...
Prevention of Further Absorption of Poison