Related Experiment Video
Updated: Feb 9, 2026

Creation of Two Saccular Elastase-Digested Aneurysms with Different Hemodynamics in One Rabbit
Published on: April 15, 2021
Morphometry and hemodynamics of posterior communicating artery aneurysms: Ruptured versus unruptured
Xu Huang1, Donghui Liu2, Xiaoping Yin3
1Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing, China; PKU-HKUST Shenzhen-Hongkong Institution, Shenzhen, China.
Abstract:
Posterior communicating artery (PCoA) aneurysms frequently rupture in small size (<7 mm). The aim of the study is to demonstrate morphometric and hemodynamic analyses in ruptured and unruptured PCoA aneurysms to improve predictive accuracy for rupture. Geometrical models were reconstructed from rotational DSA images of 57 ruptured and 22 unruptured side-wall PCoA aneurysms, which were classified into four two-dimensional (2D) groups by a combination of H/D and H/S ratios (H: dome height, D: dome diameter, and S: semi-axis height). Surface area ratio (SAR) of low time-averaged wall shear stress (TAWSS, ≤4 dynes cm-2) and high oscillatory shear index (OSI, ≥0.15) were computed in aneurysms. We hypothesized that a two-step analysis method, i.e., one-dimensionally morphometric and hemodynamic analyses in each 2D group, can enhance accuracy of PCoA aneurysm rupture evaluation. There was the highest incidence of H/D > 1 and H/S ≤ 2 with the largest surface area and SAR-TAWSS, but the lowest incidence of H/D ≤ 1 and H/S > 2 with the smallest surface area and SAR-TAWSS in ruptured PCoA aneurysms. PCoA aneurysms of H/D > 1 and H/S ≤ 2 with surface area > 70 mm2, H/D ≤ 1 and H/S > 2 with neck diameter > 2.3 mm, H/D ≤ 1 and H/S ≤ 2 with aneurysmal height/parent diameter ratio > 1.0, and H/D > 1 and H/S > 2 with aneurysmal angle > 115° need special attention for clinical diagnosis and treatment. The study highlighted the importance of the two-step analysis method for clinical evaluation of PCoA aneurysm rupture.
More Related Videos
11:58Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms
Published on: August 11, 2015
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Related Concept Videos
Communication
Communication
Aneurysm I: Introduction
Neuronal Communication
Therapeutic Communication
Verbal communication depends on language or a prescribed way of using words so that people can share information effectively. The critical aspects of verbal...
Barriers to Effective Communication II
Cultural barriers:
Differences in values, beliefs, religion, knowledge, and tradition can significantly impact communication. Awareness of nonverbal cues is critical, especially when conversing with a patient from a different culture. What appears appropriate in one culture may be inappropriate in another.
Semantic barriers:
As a result of their tendency to use...