Non-inverted pedicle internal limiting membrane transposition for large macular holes
Zizhong Hu1, Xiaojian Ye1, Xuehua Lv1
1Department of Ophthalmology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
Purpose:
The purpose of this study is to investigate the effectiveness of a new surgical technique of non-inverted pedicle internal limiting membrane (ILM) transposition for the treatment of eyes with large macular hole.
Methods:
This is a retrospective, consecutive, interventional case series. Twelve eyes of 12 consecutive patients who underwent vitrectomy for the treatment of a large macular hole (MH size > 400 µm) were treated. ILM was peeled and left with a pedicle attached to the superior temporal retina. The macular hole was covered by transposition of the pedicle ILM in a non-inverted way. Preoperative and postoperative best-corrected visual acuity (BCVA), SD-OCT image, macular sensitivity by microperimetry, and multifocal electroretinogram (mERG) response were evaluated. All of the patients were followed for more than 3 months.
Results:
Postoperative OCT examination confirmed 11 of 12 macular hole closed (91.7%). Six macular hole filled with silicone oil closed as early as the next day. The postoperative BCVA significantly increased compared with preoperative BCVA (P = 0.002). The improvement of macular sensitivity within 2° and 8° circle was also statistical significant (P = 0.018 and P = 0.017, respectively). Fixation stability, shown as the percentage of fixation point within the 2° circle and 4° circle, was remarkably improved (P = 0.017 and P = 0.018, respectively). The R1/R2 and R1/R4 ring ratios also increased significantly as compared with that of baseline.
Conclusion:
These findings indicate that the non-inverted pedicle ILM transposition results in a high incidence of anatomic closure with good visual outcome for the treatment of large macular hole.
Related Concept Videos
Overview of Transposition and Recombination
Inverting and Non-inverting OpAmps
Internal Receptors
Limiting Reactant
Internal Energy
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.