Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Bioavailability Study Design: Absolute Versus Relative Bioavailability01:27

Bioavailability Study Design: Absolute Versus Relative Bioavailability

365
Bioavailability is a crucial pharmacokinetic parameter that quantifies the proportion of an administered drug that reaches the systemic circulation and is available for therapeutic action. Regulatory agencies mandate the assessment of bioavailability, typically measured as the area under the drug plasma concentration-versus-time curve (AUC), to ensure the efficacy and safety of pharmaceutical products. These evaluations are categorized as absolute and relative bioavailability studies.Absolute...
365
Absolute Value Inequalities01:23

Absolute Value Inequalities

344
The absolute value is a mathematical tool that represents the distance of a number from zero on the number line, regardless of its sign. In the context of inequalities, absolute value expressions help define a range of permissible values or boundaries for a variable. These inequalities are commonly used in scientific modeling and data interpretation, where variability within or beyond a certain threshold must be captured precisely.An absolute value inequality of the form ∣x∣ ≤...
344
Mean Absolute Deviation01:13

Mean Absolute Deviation

3.4K
The mean absolute deviation is also a measure of the variability of data in a sample. It is the absolute value of the average difference between the data values and the mean.
Let us consider a dataset containing the number of unsold cupcakes in five shops: 10, 15, 8, 7, and 10. Initially, calculate the sample mean. Then calculate the deviation, or the difference, between each data value and the mean. Next, the absolute values of these deviations are added and divided by the sample size to...
3.4K
Absolute and Local Extreme Values01:22

Absolute and Local Extreme Values

86
The highest and lowest values of a function, relative to a reference axis, are known as extreme values. These include absolute maximum and absolute minimum values, which represent the highest and lowest points the function reaches across its entire domain. Within a restricted portion of the function, the highest and lowest values are referred to as local maximum and local minimum values, respectively.Periodic functions, such as sine and cosine, show extreme values at infinitely many points due...
86
Absolute Motion Analysis- General Plane Motion01:24

Absolute Motion Analysis- General Plane Motion

579
Visualize a drone, with its propellers spinning rapidly, hovering mid-air. The fascinating movements and operations of this drone can be comprehended by applying the principle of general plane motion.
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
579
Case Studies01:22

Case Studies

13.7K
There are many research methods available to psychologists in their efforts to understand, describe, and explain behavior and the cognitive and biological processes that underlie it.
13.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Improved patient models for simulation of clinically realistic <sup>68</sup>Ga-SSTR PET and <sup>177</sup>Lu-PRRT SPECT studies.

EJNMMI physics·2026
Same author

A data-driven respiratory motion correction for pediatric DMSA renal SPECT imaging: A simulation study.

Medical physics·2026
Same author

A validation protocol for<sup>177</sup>Lu-SPECT image quantification as a basis for multi-centre kidney dosimetry.

Physics in medicine and biology·2025
Same author

Accuracy of a whole-body single-photon emission computed tomography with a thallium-bromide detector: Verification via Monte Carlo simulations.

Medical physics·2025
Same author

Pareto optimization of SPECT acquisition and reconstruction settings for <sup>177</sup>Lu activity quantification.

EJNMMI physics·2024
Same author

Evaluation of Improved Imaging Properties with Tungsten-Based Parallel-Hole Collimators: A Monte Carlo Study.

World journal of nuclear medicine·2024

Related Experiment Video

Updated: Feb 9, 2026

Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
09:22

Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry

Published on: August 13, 2021

2.8K

Absolute Quantitation of SPECT Studies.

Michael Ljungberg1

  • 1Department of Medical Radiation Physics, Lund University, Lund, Sweden.

Seminars in Nuclear Medicine
|June 2, 2018
PubMed
Summary
This summary is machine-generated.

Accurate quantitative SPECT imaging requires compensation for physical effects like photon attenuation and scatter, alongside camera-specific issues. Precise calibration is crucial for reliable activity estimates in organs and tissues.

More Related Videos

Absolute Quantification of Plasma MicroRNA Levels in Cynomolgus Monkeys, Using Quantitative Real-time Reverse Transcription PCR
10:23

Absolute Quantification of Plasma MicroRNA Levels in Cynomolgus Monkeys, Using Quantitative Real-time Reverse Transcription PCR

Published on: February 12, 2018

12.0K
High Throughput, Absolute Determination of the Content of a Selected Protein at Tissue Levels Using Quantitative Dot Blot Analysis QDB
08:10

High Throughput, Absolute Determination of the Content of a Selected Protein at Tissue Levels Using Quantitative Dot Blot Analysis QDB

Published on: August 21, 2018

11.6K

Related Experiment Videos

Last Updated: Feb 9, 2026

Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
09:22

Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry

Published on: August 13, 2021

2.8K
Absolute Quantification of Plasma MicroRNA Levels in Cynomolgus Monkeys, Using Quantitative Real-time Reverse Transcription PCR
10:23

Absolute Quantification of Plasma MicroRNA Levels in Cynomolgus Monkeys, Using Quantitative Real-time Reverse Transcription PCR

Published on: February 12, 2018

12.0K
High Throughput, Absolute Determination of the Content of a Selected Protein at Tissue Levels Using Quantitative Dot Blot Analysis QDB
08:10

High Throughput, Absolute Determination of the Content of a Selected Protein at Tissue Levels Using Quantitative Dot Blot Analysis QDB

Published on: August 21, 2018

11.6K

Area of Science:

  • Nuclear Medicine
  • Medical Imaging Physics

Background:

  • Single-photon emission computed tomography (SPECT) imaging aims for absolute quantitation of radiotracer uptake in organs and tissues.
  • SPECT images are inherently affected by physical and camera-specific factors that compromise accuracy and precision.
  • Accurate quantitation is essential for reliable diagnosis and treatment monitoring in various clinical applications.

Purpose of the Study:

  • To review and summarize essential compensation methods for improving quantitative SPECT accuracy.
  • To discuss the implementation of these compensation techniques within iterative reconstruction algorithms.
  • To highlight current and future applications where quantitative SPECT is critically important.

Main Methods:

  • Detailed explanation of physical effects impacting SPECT quantitation: photon attenuation, Compton scatter, and collimator response.
  • Discussion of camera-specific effects: dead time and pulse pile-up, and their influence on activity estimates.
  • Emphasis on the necessity of rigorous calibration for translating image counts to absolute activity concentrations.

Main Results:

  • Identified key factors degrading SPECT image quality and activity quantitation accuracy.
  • Outlined compensation strategies integrated into iterative reconstruction for enhanced precision.
  • Demonstrated the feasibility of achieving more accurate activity estimates through comprehensive correction methods.

Conclusions:

  • Effective compensation for physical and camera-specific effects is paramount for accurate SPECT quantitation.
  • Iterative reconstruction provides a robust framework for implementing these advanced compensation methods.
  • Quantitative SPECT holds significant promise for future advancements in clinical diagnostics and therapeutic assessments.