A data-driven respiratory motion correction for pediatric DMSA renal SPECT imaging: A simulation study.
Justin Pijanowski1,2, P Hendrik Pretorius1, W Paul Segars3
1Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA.
This study developed a data-driven method to correct respiratory motion in pediatric Technetium-99m-dimercaptosuccinic acid (DMSA) renal SPECT imaging. The technique improved image quality, particularly for moderate motion, potentially enhancing diagnostic accuracy.
Area of Science:
- Medical Imaging
- Nuclear Medicine
- Pediatric Imaging
Background:
- Technetium-99m-dimercaptosuccinic acid (DMSA) renal scintigraphy is crucial for evaluating pediatric urinary tract infections.
- Pyelonephritis and scarring appear as defects on DMSA renal scintigraphy, including SPECT imaging.
- Respiratory motion degrades SPECT image quality, necessitating motion correction.
Purpose of the Study:
- Develop and evaluate a data-driven method for estimating respiratory motion signals.
- Apply these signals to correct respiratory motion in pediatric DMSA renal SPECT imaging.
- Improve diagnostic accuracy through enhanced image quality.
Main Methods:
- Utilized XCAT phantom and SPECT Monte Carlo simulation for 100 ms projections.
- Employed axial center-of-count-mass (aCOM) to estimate surrogate respiratory signals.
- Reconstructed images across seven motion states and applied rigid-body registration for motion correction.
Main Results:
- Achieved a Pearson's correlation coefficient (r) of 0.76 between estimated and true respiratory motion.
- Demonstrated significant improvement in Normalized Root Mean Square Error (NRMSE) with motion correction for motion amplitudes >10 mm.
- No significant difference in NRMSE for motion amplitudes between 6-10 mm.
Conclusions:
- Data-driven respiratory motion correction enhances pediatric renal SPECT image quality.
- The method shows potential for improved diagnostic accuracy in studies with moderate motion.
- Further validation is recommended for clinical application.