Related Experiment Video
Updated: Feb 9, 2026

Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Comparison of two analytical methods validated for the determination of volatile compounds in virgin olive oil:
R Aparicio-Ruiz1, D L García-González2, M T Morales1
1Department of Analytical Chemistry, Universidad de Sevilla, c/ Prof. García González 2, 41012 Sevilla, Spain.
Abstract:
The utility of volatile compounds to explain virgin olive oil aroma descriptors is fully accepted and demanded by the olive oil sector. However, the methodology, and particularly the kind of detector to be used, is a matter of discussion because the high number of volatiles and their different nature. The SPME-GC-MS method has recently been validated for the most relevant volatiles but SPME-GC-FID method still needs to be validated to evaluate its performance in this application. A comparison between these two GC methods in determining 26 volatiles has been carried out in terms of analytical quality parameters (repeatability, intermediate precision, calibration curves, limits of detection and quantification, linear working ranges, selectivity and sensitivity). Good selectivity, linearity and higher upper values of the working range are the main advantages of SPME-GC-FID versus low bottom values of working ranges, better sensitivity and lower limits of detection and quantification of SPME-GC-MS. The limit of blank associated to each individual volatile was also determined and it allowed perfecting the empirical limit of detection. This procedure was carried out for SPME-GC-FID, which resulted in 21 volatiles with empirical limits of detections lower than their odor thresholds, and hence they can be used as markers of virgin olive oil sensory descriptors. Finally, with all the analytical quality parameters checked, a practical example of the ability of the volatiles quantified by SPME-GC-FID to discriminate the different categories (extra-virgin, virgin and lampante) and their main aroma descriptors is also provided.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
11:07Isolation of Mandibular Gland Reservoir Contents from Bornean 'Exploding Ants' Formicidae for Volatilome Analysis by GC-MS and MetaboliteDetector
Published on: August 26, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Development of Analytical Methods
Volatilization
Reliability and Validity
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Classification of Elements and Compounds
Compounds are pure substances composed of two or more elements in fixed, definite proportions. Compounds are classified as ionic or molecular (covalent) based on the bonds...