Related Experiment Video
Updated: Feb 9, 2026

Measuring the Behavioral Effects of Intraocular Scatter
Published on: February 18, 2021
Measurement of tear production and intraocular pressure in conscious captive European fallow deer (DAMA dama)
Rebecca E Pacheco1, Bianca S Bauer1, Miranda J Sadar1
1Department of Small Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, Saskatchewan, Canada.
Abstract:
Normal values for intraocular pressure (IOP) and tear production in conscious cervids have not been reported to date. Based on trends in zoological institutions to perform non-anaesthetized health exams, it is applicable to establish normal values in conscious animals, as anaesthesia and sedation can alter these parameters. The goal of this study was to estimate intraocular pressures using rebound tonometry and measure tear production values in a group of healthy, conscious, European fallow deer utilizing chute restraint. Evaluation of these values with regards to instrumentation and restraint variables will be assessed. Complete ophthalmic examinations, including estimation of IOP with rebound tonometry and measurement of tear production with Schirmer tear tests (STT) were performed on nine conscious European fallow deer (Dama dama) restrained in a chute. Correlations between IOP on the unspecified (P) and the equine (H) settings, as well as IOP and STT differences between left (OS) and right (OD) eyes were evaluated, in addition to assessment of correlations between right and left lateral recumbency on IOP and STT. Tear production measurements were 18.7 ± 5.1 mm min-1 with a 95% confidence interval (CI) range of 16.4-21.1 mm min-1 . Intraocular pressure measurements for the P setting were 16.1 ± 4.5 mmHg with a 95% CI range of 14.1-18.2 mmHg, and for the H setting were 21.5 ± 5.1 mmHg with a 95% CI range of 19.1-23.9 mmHg. No statistically significant difference (P > 0.05) was found between OS and OD in any test. Neither left nor right lateral recumbency was found to have a statistically significant effect on IOP or STT. This study represents the first assessment of ophthalmic parameters in conscious fallow deer with rebound tonometry and STT.
More Related Videos
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Understanding Consciousness
Sleep, a crucial state, is characterized by reduced...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

