In vivo time-gated diffuse correlation spectroscopy at quasi-null source-detector separation

Optics Letters
|June 2, 2018
PubMed
Summary

We developed a new time-gated diffuse correlation spectroscopy method for measuring blood flow. This technique simplifies instrumentation and reduces probe size for enhanced in-vivo measurements.

Related Concept Videos

Drug Concentration Versus Time Correlation01:15

Drug Concentration Versus Time Correlation

The plasma drug concentration-time curve is a crucial tool in pharmacokinetics, representing the drug's concentration in plasma at different time intervals post-administration. This curve illustrates the drug's journey from absorption into the systemic circulation, distribution to body tissues, and eventual elimination through excretion or biotransformation.
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
2.2K
2D NMR: Homonuclear Correlation Spectroscopy (COSY)01:06

2D NMR: Homonuclear Correlation Spectroscopy (COSY)

Homonuclear correlation spectroscopy, or COSY, is a 2-dimensional NMR technique that provides information about coupled protons. Typically, the geminal and vicinal coupling are observed. For example, consider the COSY spectrum of ethyl acetate, where its 1D proton NMR spectrum is plotted along the vertical and horizontal axes with their corresponding chemical shift scale. Three spots on the diagonal corresponding to the three peaks in the 1D proton spectrum are called diagonal peaks. The COSY...
2.0K
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
1.3K
Diffusion01:12

Diffusion

Diffusion is the passive movement of substances down their concentration gradients—requiring no expenditure of cellular energy. Substances, such as molecules or ions, diffuse from an area of high concentration to an area of low concentration in the cytosol or across membranes. Eventually, the concentration will even out, with the substance moving randomly but causing no net change in concentration. Such a state is called dynamic equilibrium, which is essential for maintaining overall...
221.0K
Correlations02:20

Correlations

Correlation means that there is a relationship between two or more variables (such as ice cream consumption and crime), but this relationship does not necessarily imply cause and effect. When two variables are correlated, it simply means that as one variable changes, so does the other. We can measure correlation by calculating a statistic known as a correlation coefficient. A correlation coefficient is a number from -1 to +1 that indicates the strength and direction of the relationship between...
36.5K
Correlation and Causation01:27

Correlation and Causation

Statistical tests can calculate whether there is a relationship, or correlation, between independent and dependent variables. An indirect relationship of the variables signifies a correlation, while a direct relationship shows causation. If it is determined that no connection exists between the variables, then the correlation is a coincidence.
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
42.9K