Related Experiment Video
Updated: Feb 9, 2026

Point-of-Care Ultrasound: A Review of Ultrasound Parameters for Predicting Difficult Airways
Published on: April 7, 2023
Finding the right spot: Where to measure airway parameters in patients with COPD
Joshua Gawlitza1, Holger Haubenreisser1, Thomas Henzler1
1Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
Purpose:
The importance of spirometry for management of COPD was reduced in the 2017 revision of the GOLD report. CT derived airway measurements show strong correlations with lung function tests and symptoms. However, these correlations are specific to the airway localization, and currently there is no evidence for the ideal spot. Therefore, the aim of this prospective study was to systematically correlate CT derived airway measurements with extensive lung function testing.
Methods And Materials:
65 patients with diagnosed COPD underwent body plethysmography, impulse oscillometry and dose optimized qCT examination (Somatom Force, Healthineers, Germany) in inspiration and expiration. Eight airway parameters (e.g. outer diameter, maximal wall thickness) were acquired for both scans in every lobe for the third to fifth generation bronchus and correlated with the lung function tests.
Results:
The most significant correlations between airway parameters were found for the third generation bronchus of the upper left lobe during expiration (25 out of 48 correlation pairs, mean r = -0.39) and for the third generation bronchus of the upper right lobe during inspiration (9 out of 48 correlation pairs, mean r = -0.25). No significant correlations were for example found for the upper right lobe in expiration.
Conclusion:
Correlations between airway parameters and lung function tests vary widely between lobes, bronchus generations and breathing states. Our work suggests that the third generation bronchus of the upper left lobe in expiration could be the preferred localization for airway quantification in future studies.
More Related Videos
10:37Automated Measurement of Pulmonary Emphysema and Small Airway Remodeling in Cigarette Smoke-exposed Mice
Published on: January 16, 2015
10:18Real-Time, Semi-Automated Fluorescent Measurement of the Airway Surface Liquid pH of Primary Human Airway Epithelial Cells
Published on: June 13, 2019
Related Concept Videos
COPD: Pathogenesis and Clinical Features
The primary cause for the onset of COPD is cigarette smoking and exposure to air pollution. These hazardous factors initiate a chain reaction within the lungs, resulting in chronic inflammation, damage to the airways, and a...
COPD: Management Using Bronchodilators and Corticosteroids
Finding the Center of Gravity
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...