Related Experiment Video
Updated: Feb 9, 2026

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
Published on: July 23, 2016
Validated LC-MS/MS method for the determination of amlodipine enantiomers in rat plasma and its application to a
Lijuan Wang1, Wenxia Liu1, Zunjian Zhang2
1Key Laboratory of Drug Quality Control and Pharmacovigilance, China Pharmaceutical University, 24 Tongjia lane, Nanjing 210009, China; Key Laboratory of Drug Consistency Evaluation, China Pharmaceutical University, Nanjing 210009, China.
Abstract:
A rapid and sensitive method was established to determine amlodipine enantiomers using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Stereoselective separation was performed on CHIRALCEL OZ-RH column (150 mm × 4.6 mm i.d., 5 μm) with acetonitrile-water (10 mM ammonium acetate, 0.5% ammonia solution) (95:5, v/v) at a flow rate of 0.5 mL/min. The substances were detected by mass spectrometer equipped with an electrospray ionization source interface in positive ion mode. Multiple reaction monitoring was selected with the transition of the m/z 409.1 → 238.0 for amlodipine enantiomers and m/z 237.0 → 194.1 for carbamazepine (IS) respectively. Calibration curves were linear at the range of 0.9375-120 ng/mL for both isomers with r > 0.99, while using a lower sample volume (50 μL) compared with previously reported enantiospecific methods The accuracy was at the range of 84.1-119.0% for R-amlodipine, and 87.4-118.2% for S-amlodipine, respectively. The within- and between-run precision (CV%) was within 10% in all cases for both enantiomers. Enantiomers were stable under different conditions, e.g. processed sample, short-term, residue, long-term and freeze/thaw. The LC-MS/MS method was successfully applied in pharmacokinetic study of amlodipine enantiomers in rats. It was observed the concentration of the S- amlodipine was significantly higher than that of the R-amlodipine in racemate-treated group. And there was no significant difference in the pharmacokinetic profiles of the S-amlodipine between the 10 mg/kg racemate- and 5 mg/kg S-amlodipine-treated groups. In addition, it was the first time to find that the main pharmacokinetic parameters (AUC(0-t), AUC(0-∞) and Cmax) of R-amlodipine were significantly lower in the 5 mg/kg R-amlodipine-treated group compared with the racemate-treated group.
Related Concept Videos
Naming Enantiomers
Measurement of Bioavailability: Pharmacokinetic Methods
Reliability and Validity
Properties of Enantiomers and Optical Activity
Racemic Mixtures and the Resolution of Enantiomers
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...