Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a
Eduard Rott1, Tobias Reinhardt2, Stephan Wasielewski2
1Institute for Sanitary Engineering, Water Quality and Solid Waste Management, University of Stuttgart; eduard.rott@iswa.uni-stuttgart.de.
Abstract:
This paper introduces a procedure to investigate the adsorption of phosphonates onto iron-containing filter materials, particularly granular ferric hydroxide (GFH), with little effort and high reliability. The phosphonate, e.g., nitrilotrimethylphosphonic acid (NTMP), is brought into contact with the GFH in a rotator in a solution buffered by an organic acid (e.g., acetic acid) or Good buffer (e.g., 2-(N-morpholino)ethanesulfonic acid) [MES] and N-cyclohexyl-2-hydroxyl-3-aminopropanesulfonic acid [CAPSO]) in a concentration of 10 mM for a specific time in 50 mL centrifuge tubes. Subsequently, after membrane filtration (0.45 µm pore size), the total phosphorus (total P) concentration is measured using a specifically developed determination method (ISOmini). This method is a modification and simplification of the ISO 6878 method: a 4 mL sample is mixed with H2SO4 and K2S2O8 in a screw cap vial, heated to 148-150 °C for 1 h and then mixed with NaOH, ascorbic acid and acidified molybdate with antimony(III) (final volume of 10 mL) to produce a blue complex. The color intensity, which is linearly proportional to the phosphorus concentration, is measured spectrophotometrically (880 nm). It is demonstrated that the buffer concentration used has no significant effect on the adsorption of phosphonate between pH 4 and 12. The buffers, therefore, do not compete with the phosphonate for adsorption sites. Furthermore, the relatively high concentration of the buffer requires a higher dosage concentration of oxidizing agent (K2S2O8) for digestion than that specified in ISO 6878, which, together with the NaOH dosage, is matched to each buffer. Despite the simplification, the ISOmini method does not lose any of its accuracy compared to the standardized method.
Related Concept Videos
Experimental Determination of Chemical Formula
Determining the pH of Salt Solutions
Determining Order of Reaction
Determination
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...