Related Experiment Video
Updated: Feb 9, 2026

Long-term High-Resolution Intravital Microscopy in the Lung with a Vacuum Stabilized Imaging Window
Published on: October 6, 2016
A comprehensive theoretical comparison of proton imaging set-ups in terms of spatial resolution
N Krah1,2, F Khellaf1, J M Létang1
1Lyon University, INSA-Lyon, University Lyon1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR5220, U1206, France.
Abstract:
We present a comprehensive analytical comparison of four types of proton imaging set-ups and, to this end, develop a mathematical framework to calculate the width of the uncertainty envelope around the most likely proton path depending on set-up geometry, detector properties, and proton beam parameters. As a figure of merit for the spatial resolution achievable with each set-up, we use the frequency [Formula: see text] at which the modular transfer function of a density step decreases below 10%. We verify the analytical results with Monte Carlo simulations. We find that set-ups which track the angle and position of individual protons in front of and behind the phantom would yield an average spatial resolution of 0.3-0.35 lp mm-1 assuming realistic geometric parameters (i.e. 30-40 cm distance between detector and phantom, 15-20 cm phantom thickness). For set-ups combining pencil beam scanning with either a position sensitive detector, e.g. an x-ray flat panel, or with a position insensitive detector, e.g. a range telescope, we find an average spatial resolution of about 0.1 lp mm-1 for an 8 mm FWHM beam spot size. The pixel information improves the spatial resolution by less than 10%. In both set-up types, performance can be significantly improved by reducing the pencil beam size down to 2 mm FWHM. In this case, the achievable spatial resolution reaches about 0.25 lp mm-1. Our results show that imaging set-ups combining double scattering with a pixel detector can provide sufficient spatial resolution only under very stringent conditions and are not ideally suited for computed tomography applications. We further propose a region-of-interest method for set-ups with a pixel detector to filter out protons which have undergone nuclear reactions and discuss the impact of tracker detector uncertainties on the most likely path.
More Related Videos
Related Concept Videos
Documentation in Long-Term and Home Healthcare Setting
Long-Term Care Facilities
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Theoretical Approaches to Psychological Disorder
Biological approach
The biological approach posits that internal, organic factors are the primary causes of such disorders. This perspective emphasizes brain structure and function, genetic predispositions, and neurotransmitter imbalances. For example, schizophrenia has been associated with both genetic...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Long-term Depression

