Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version
Mohammad Ali Alzohiry1, Mohammad Kamal Abdelnasser2, Mohamed Moustafa1
1Orthopedic Department, Assiut University Hospital, Assiut, Egypt.
Introduction:
Acetabular cup version is crucial for successful total hip arthroplasty (THA). Many methods have been described for measurement of cup version angle. The aim of this study is to assess the accuracy of five commonly used methods for measurement of acetabular cup version in plain antero-posterior views of the pelvis and hip.
Material And Methods:
Sixty primary THA cases were subjected postoperatively to plain A-P of the pelvis (AP-P), A-P view of the hip (AP-H), and computed tomography (CT) imaging. The acetabular cup version was measured in AP-P and AP-H by five methods (Lewinnek, Widmer, Hassan et al., Ackland et al., and Liaw et al.). These measurements were compared to the CT measurement.
Results:
All plain X-ray methods showed no significant differences from the CT, except those of Hassan et al. in AP-H, and Widmer and Ackland et al. in AP-P.
Conclusions And Recommendations:
For measurement of acetabular cup version angle, we recommend the use of Lewinnek and Liaw et al. methods both in AP-P and in AP-H, while Hassan et al.'s method is recommended in AP-P only, and Widmer and Ackland et al.'s methods in AP-H only.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Improving Translational Accuracy
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...