Related Experiment Video
Updated: Feb 9, 2026

Reusable Single Cell for Iterative Epigenomic Analyses
Published on: February 11, 2022
Single-use versus reusable ureterorenoscopes for retrograde intrarenal surgery (RIRS): systematic comparative
Susanne Deininger1, Luis Haberstock1, Stephan Kruck1
1Department of Urology, Eberhard-Karls-University Tübingen, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany.
Introduction:
Retrograde intrarenal surgery (RIRS) represents a standard option for kidney stone removal. However, RIRS is considered a cost-intensive procedure. Single-use flexible ureterorenoscopes have been introduced to improve budget predictability in RIRS. We assessed differences in physical and optical properties of single-use devices compared to standard reusable endoscopes.
Methods:
In two single-use (LithoVue™, Boston Scientific; Pusen Uscope UE3011™), and one reusable ureterorenoscope (Flex-Xc™, Karl Storz), we investigated flow rates, deflection, illuminance, and intrapelvic pressure in a porcine kidney model. Subjective image quality was assessed using a standardized questionnaire. Common insertable devices were applied to investigate additional influence on physical properties.
Results:
Significant variability in maximum flow rates was observed (Flex-Xc™: 25.8 ml/min, LithoVue™: 30.3 ml/min, Pusen™: 33.4 ml/min, p < 0.05). Insertion of a guide wire resulted in the highest reduction of flow rates in all endoscopes. Flection led to a reduction of absolute flow rates up to 9.4% (Flex-Xc™). Light intensity at 20/50 mm distance was 9090 lx/1857 lx (Flex-Xc™) and 5733 lx/1032 lx (LithoVue™) and 2160 lx/428 lx (Pusen™), respectively (p < 0.05). Subjective image quality score was highest using the Flex-Xc™ endoscope. During manipulation, maximum intrarenal pressure up to 66 mmHg (Pusen™) was measured.
Conclusions:
Significant differences in physical and optical properties of single-use or reusable flexible ureterorenoscopes are present, with putative influence on surgical efficacy and complications. Further comparative evaluation of single-use and reusable endoscopes in a clinical scenario is useful. Moreover, utilization of ureteral access sheaths may be considered to avoid renal damage.
Related Concept Videos
Physical and Chemical Properties of Matter
Physical Properties of Amines
Physical Properties Affecting Solubility
As for any solution, the solubility of a gas in a liquid is affected by the attractive intermolecular forces between solute and solvent species. Unlike solid and liquid solutes, however, there is no solute-solute intermolecular attraction to overcome when a gaseous solute dissolves in a liquid solvent since the atoms or molecules comprising a gas are far separated and experience negligible interactions. Consequently, solute-solvent interactions are the sole...
Physical Properties of Alkanes
Physical Properties of Ethers
An ether molecule has a net dipole moment due to the polarity of C–O bonds. Subsequently, boiling points of ethers are lower than those of alcohols of comparable molecular weight and slightly higher than those of hydrocarbons of comparable molecular weight (Table 1).
Ethers can act as hydrogen bond acceptors, making them more water-soluble than hydrocarbons, but since ethers cannot act as hydrogen bond donors, they are much less soluble in water than alcohols. Ethers are considered...
Urine: Physical and Chemical Properties
The concentration of these solutes varies, with urea being the most abundant nitrogenous waste product. Other solutes include sodium, chloride, potassium, phosphate,...

