An Optical Configuration of Crossed-Beam Photothermal Lens Spectrometer Operating at High Flow Velocities and Its
Javad Yoosefian1, Naader Alizadeh1
1Department of Chemistry, Faculty of Basic Sciences , Tarbiat Modares University , P.O. Box 14115-175, Tehran , Iran.
Abstract:
Photothermal lens spectrometry (TLS) is a high sensitive technique for trace determination of nonfluorescent materials. Previous photothermal lens spectrometers suffer from operating limitations at high flow velocities, arising from taking the heated element off the probe beam direction, which results in a decrease in the thermal lens (TL) signal. Herein, we describe an optical configuration of the crossed-beam photothermal lens in transversal flow mode in which the propagating direction of the probe beam and liquid sample flow azimuth are concentric (CBTC). The system consists of a microfluidic cell with a volume of lower than 3 μL. In the current optical configuration, using 1-(2-pyridylazo)-2-naphthol (PAN) in ethanol as a test solution, by increasing the sample flow velocity and without increasing chopping frequency, the reduction in sensitivity is less pronounced. Under a 15 Hz chopping frequency, the optimum sample flow velocity is about 2 cm s-1, which is among the highest reported values achieved to date for photothermal lens spectrometers. Although the system operates at higher flow velocities and lower chopping frequencies compared to the collinear configuration, it provides a comparable analytical limit of detection. This optical configuration has been successfully employed for highly sensitive and selective determination of cysteine in human serum and saliva samples through a competitive complexation reaction with Cu-PAN as a colorimetric probe. The detection limit of this method (9.5 nM) shows a significant enhancement (726-times) in comparison to UV-vis measurements.
Related Concept Videos
IR Spectrometers
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms