Related Experiment Video
Updated: Aug 10, 2025

Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Chemical reduction as a facile colorimetric approach for selective TNT detection by spectrophotometry and
Naader Alizadeh1, Javad Yoosefian1
1Department of Chemistry, Faculty of Basic Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
Abstract:
In this study, the simple determination of TNT is achieved through the vivid stable red color products generated after chemically reduction by NaBH4 as a common and accessible reducing/colorimetric reagent. Some other nitroaromatics were impressed under reduction reaction and led to the colorful products. The color of these reduced nitroaromatics were unstable and approximately vanished after some few minutes which ameliorated the selectivity in TNT determination. Utilizing the time-dependent selectivity, the method was applied specifically for discriminating of TNT from other nitroaromatic compounds (NACs). UV-vis spectrophotometry and photothermal lens spectrometry were employed as detection techniques. The former was simpler and more available in various laboratories while the latter provides higher sensitivity. It was revealed that the photothermal lens responses were linear from 2.0 to 55.0 nM with a limit of detection (LOD) of about 0.8 nM. The LOD of the photothermal lens measurement were found to be 241 times lower than that of the UV-vis spectrophotometry in TNT quantification. The evolved method was successfully carried out for TNT vapor determination after trapping into the colorimetric reagent. The recoveries and relative standard deviations (RSD, n = 3) calculated for 3 gas samples were ≥91% and ≤7%, respectively.
More Related Videos
12:07Microwave-assisted Intramolecular Dehydrogenative Diels-Alder Reactions for the Synthesis of Functionalized Naphthalenes/Solvatochromic Dyes
Published on: April 1, 2013
10:13A Technical Guide for Performing Spectroscopic Measurements on Metal-Organic Frameworks
Published on: April 28, 2023
Related Concept Videos
Photoluminescence: Applications
Redox Titration: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Redox Titration: Other Oxidizing and Reducing Agents
Flame Photometry: Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...