Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and
Kevin Y Wang1, Tomas A Uribe1, Christie M Lincoln1
1Department of Radiology, Baylor College of Medicine, Houston, TX, United States.
Purpose:
Infratentorial lesions in patients with multiple sclerosis are associated with long-term disability. Two-dimensional fluid-attenuated inversion recovery demonstrates poor infratentorial lesion detection when compared to T2-weighted spin echo. Evidence of improved detection with 3D fluid-attenuated inversion recovery has been conflicting. This study compares the infratentorial lesion detection performance, observer performance, and signal and contrast properties between T2-weighted spin echo, 2D, and 3D fluid-attenuated inversion recovery.
Methods:
Two board-certified radiologists independently reviewed and counted infratentorial lesions from 85 brain MRIs in patients with clinically definite multiple sclerosis and concurrent 3D, 2D fluid-attenuated inversion recovery, and T2-weighted spin echo sequences. Contrast-to-noise and signal-to-noise ratios were measured for 25 MRIs. Wilcoxon signed-rank test was used for pairwise comparisons of the combined average infratentorial lesion count, contrast-to-noise, and signal-to-noise ratios, and was adjusted for three pairwise comparisons using Bonferroni correction. A corrected p value < 0.05 was considered statistically significant.
Results:
The number of lesions on 3D fluid-attenuated inversion recovery was significantly higher than those on 2D (p < 0.001) and T2-weighted spin echo (p < 0.001). Results of contrast-to-noise and signal-to-noise ratios were overall mixed and predominantly not concordant with lesion count findings, with T2-weighted spin echo demonstrating the highest signal-to-noise ratios and contrast-to-noise ratio of lesion compared with white matter but the lowest contrast-to-noise ratio of lesion compared with gray matter.
Conclusion:
The 3D fluid-attenuated inversion recovery sequence addresses the disadvantage of poor infratentorial lesion detection on 2D, while still maintaining the advantage over T2-weighted spin echo in the detection of lesions adjacent to the cerebrospinal fluid.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
NMR Spectroscopy: Spin–Spin Coupling
Spin–Spin Coupling: One-Bond Coupling
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...